IMPORTANT:    BEFORE YOU BEGIN 

 

1.

 

For TOUCH SENSITIVE CONTROLS, please DO NOT PRESS.    A light touch and hold on the required button for a matter of a (1) one second is all that is 
needed.

 

2.

 

T

OUCH THE ENTIRE BUTTON: See illustration on right:

 

 

 
 
 
 

 
1.    FOR PX02 & PX06 Model: 

TYPE 1: TOUCH SCREEN CONTROL PANEL   

 

 

 
 

 
 
 
 
 
 

Importance Notice: 

1.  AUTO FUNCTION ACTIVE: Once “Auto Function” is on or touched, all other functions will be DE-ACTIVATED and will NOT be 

working. 

2.  2 ½ HOUR AUTOMATIC SHUT OFF: This range hood will be shut off for every approx. 2 ½ hours.    You can re-start operation   
      usual after it was shut off. 
3.  SCREEN TURN OFF:    This range hood is equipped with remote control and smoke sensor that will self-calibrate within 5 seconds   
    when the range hood is first electrically activated. Self-calibration will be set when the range hood beeps. LCD panel WILL TURN       
    OFF automatically after a period of inactivity and every time when plugged into electrical outlet.   

 

A.    A

CTIVATING 

N

ORMAL 

B

LOWER 

F

UNCTION

While the range hood is off,   
                    Touch 

(+) to start from lowest speed, F1 

                   

Touch 

(-) to start from Highest speed, F4 

Touch (+) or (-) again to change the blower speed as indicated in LCD panel 

 
B.    Activating Light Function: 

 
Touch 

Light 

button to turn the lights on or off.   

 

C.    Activating Power-Off Delay Function: 

1.  While the range hood is on and the blower is running in normal mode, touch 

Power-Off Delay 

button to activate delay off timer.   

2.

  Adjust to desired period of delay of timer by touching (-)

 

or (+)

 

button quickly (1-15 minutes). Timer begins to countdown immediately, when it       

reaches 0, the blower will shut off.

 

3.

  Display screen will show flashing clock if timer is working.

 

 
D.    Activating Smoke Detector Function: 

                                While the machine is off, touch 

Auto Function 

button to activate the smoke detector auto function mode.   

  NOTE: this function will only worked when there’s a lot of smoke.    Once this button is touched, all other buttons are not active. 

 

E.    Changing the clock (only available in some models) 

          While the blower is off: 

          1. Touch power sign once. The hour indicator will be flashing. 
          2. Use (+) or (-) to adjust to the desired hour. 
          3. Touch power sign again for the “minutes”. Indicator will be flashing. 
          4. Use (+) or (-) to adjust to desired minutes. 
          5. Touch power sign again to clear the screen. Touch light button to validate. To check time, touch light button. 
              NOTE: The clock display is only available for product manufactured after October 2013. 

For best results, Start the range hood before 
cooking and allow it to operate several minutes 
after the cooking is completed to clear all smoke 
and odors from the kitchen.

   

 

11. RANGE HOOD OPERATION 

 

 

00 = blower off 
F1 = quiet speed 
F2 = low speed 
F3 = medium speed 
F4 = high speed 

 

 

 

 

 

 

 

INCORRECT 

VS. 

Button is NOT completely covered

Entire button covered and lightly touched. 

 

CORRECT 

Summary of Contents for Deluxe DL08-W36

Page 1: ...IONS FOR RESIDENTIAL INDOOR USE ONLY Pro X Series PX01 W30 36 PX02 W30 36 PX03 W30 36 PX04 W30 36 42 PX04 W30 36 42 B PX06 W30 36 42 48 Ultra Series D02 W30 36 UL02 W30 36 UL03 W30 36 Deluxe Series DL08 W36 42 48 INSTALLATION GUIDE USER S MANUAL WALL MOUNT RANGE HOOD ...

Page 2: ...is intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professionals and in accordance with all applicable codes and standards including fire related construction When cutting or drilling into the wall or ceiling do not damage electrical wiring and other utilities It is recommended tha...

Page 3: ...all joints with aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If the roof or wall cap has a damper you may opt out from usage of your range hood supplied damper for some models only For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommended...

Page 4: ... 2 2 2 2 2 W A S WALL ANCHOR SCREW 4 4 4 4 4 4 4 4 4 C S UPPER INNER CHIMNEY SCREW 4 ATTACHE D 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED C G CAPONY GLASS 1 N A N A N A N A N A N A N A ATTACHE D B F BAFLE FILTERS 2 3 2 30 3 36 N A ATTACH ED ATTACH ED 3 4 ATTACH ED A P ALUMINUM PIPE 1 1 1 1 1 1 1 0 1 A D AIR DIVERTER N A N A N A N A N A N A N A 1 N A D C...

Page 5: ...www XtremeAirUsa com PAGE 5 8 HOOD DIMENSIONS INSTALLATION OVERVIEW PX08 W36 42 PX04 W30 36 42 PX06 W30 36 42 PX08 W48 PX02 W30 36 UL02 W30 36 PX03 W30 36 UL03 W30 36 PX01 W30 36 ...

Page 6: ...B Level the hood body by using horizontal level C Use hand screw driver to tighten those 2 mounting screws D Connect the exhaust on the hood to the ductwork above E Use aluminum tape to make all joints secure and all tight F Find the three pronged plug and connect to an electrical outlet CAUTION Do not release the hood until you finish step 6 below STEP 2 MARKING ON THE WALL A Center is the center...

Page 7: ...d Operation Try a few test runs to ensure machine is running properly STEP 6A FOR PX01 MODEL ONLY INSTALL GLASS CANOPY A Loosen the four canopy screws and washers from the hood top B Carefully place the canopy glass on the hood top then slightly tighten the four canopy screws along with washers DO NOT put excessive pressure against the glass 10 BAFLE FILTERS INSTALL REMOVAL IMPORTANCE FOR THOSE MO...

Page 8: ...tion 1 While the range hood is on and the blower is running in normal mode touch Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay of timer by touching or button quickly 1 15 minutes Timer begins to countdown immediately when it reaches 0 the blower will shut off 3 Display screen will show flashing clock if timer is working D Activating Smoke Detector Function ...

Page 9: ...ll remain the same the next time it is turned on B ADJUSTING BLOWER SPEED Touch and hold down for increase Touch and hold down for decrease C TURNING OFF THE BLOWER Touch and hold down power sign 1 for 1 2 seconds D TO TURN THE LIGHT ON OFF Touch Light button 6 once to turn on the lights and once again to turn off the lights E ADJUSTING THE TIMER FUNCTION While the blower motor is not running touc...

Page 10: ...otice 1 If the range hood or lights does not operate after installation Check if the range hood has been plugged in Make sure that all power has been turned back ON Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs 2 The range hood vibrates when the blower is on The range hood might not have been secured properly to the cabinet or wall Check if the blowe...

Page 11: ...commended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal operation clean range hood and all baffle spacer filter grease tunnel oil container regularly Regular care will help preserve the appearance of the range hood Clea...

Page 12: ...www XtremeAirUsa com PAGE 12 16 LIMITED WARRANTY ...

Reviews: