Xtreme Power Conversion Corporation
V80 User’s Manual
Page 3
Uninterruptible Power Supply
Important Safety Warning
This manual contains important safety instructions. Please read and follow all instructions carefully during installa
-
tion and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your
UPS.
Transportation
• Please transport the UPS system only in the original package to protect against shock and impact.
Preparation
• Condensation may occur if the UPS system is moved directly from cold to warm environment. The UPS
system must be absolutely dry before being installed. Please allow at least two hours for the UPS system
to acclimate the environment.
• Do not install the UPS system near water or in moist environments.
• Do not install the UPS system where it would be exposed to direct sunlight or near heater.
• Do not block ventilation holes in the UPS housing.
Installation
How to determine the power requirements of your equipment
1. Ensure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS
unit’s rated capacity. If rated unit capacities are exceeded, an overload condition may occur and
cause the UPS unit to shut down or the fuse blow.
2. There are many factors that can affect the amount of power that your computer system will require.
For optimal system performance keep the load below 80% of the unit’s rated capacity.
Hardware Installation Guide
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8
hours is recommended to ensure that the battery’s maximum charge capacity is achieved. Charge loss
may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC
outlet. The unit will charge in both the on and off position.
2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered
data storage device.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet
is protected by a fuse or circuit breaker and does not service equipment with large electrical demands.
• To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area
free of conductive contaminants. (See the specifications for the acceptable temperature and humidity
range.)
• To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit
to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.
• Do not attach non-computer-related items, such as medical equipment, life-support equipment, micro
-
wave ovens, or vacuum cleaners to UPS.
• Do not plug the UPS input into its own output.
• Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-
containing vessels on or near the unit.
• In the event of an emergency, press the OFF button and disconnect the power cord from the AC power
supply to properly disable the UPS.