Obtaining Service

If the UPS requires Service:

1. 

Use the TROUBLESHOOTING section in this manual to eliminate obvious causes.

2. 

Verify there are no circuit breakers tripped.

3.  Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem, call Xtreme 

Power Conversion Corp Technical Support at 800.582.4524. Technical support inquiries can also be made at 

 

[email protected]

. Please have the following information available BEFORE calling the Technical Support 

Department:

•  Your name and address.

•  The serial number of the unit.

•  Where and when the unit was purchased.

•  All of the model information about your UPS.

•  Any information on the failure, including LED’s that may or may not be illuminated.

•  A description of the protected equipment, including model numbers if possible.

•  A technician will ask you for the above information and, if possible, help solve your problem over the 

phone. In the event that the unit requires factory service, the technician will issue you a Return Mate

-

rial Authorization number (RMA).

If you are returning the UPS to Xtreme Power for service, please follow these procedures:

1. 

Pack the UPS in its original packaging. If the original packaging is no longer available, ask the Technical Sup

-

port Technician about obtaining a replacement set of packaging material. It is important to pack the UPS 

properly in order to avoid damage in transit. Never use Styrofoam beads for a packing material.

2. 

Include a letter with your name, address, daytime phone number, RMA number, a copy of your original 

sales receipt, and a brief description of the problem.

3.  Mark the RMA number on the outside of all packages. Xtreme Power cannot accept any package without 

the RMA number marked on the outside of the boxes.

4.  Return the UPS by insured, prepaid carrier to the address provided by the Technician.

5. 

Refer to the Warranty statements in this manual for additional details on what is covered.

Summary of Contents for V80 Series

Page 1: ...V80 Value Series Pure Sine Wave Line Interactive UPS 700VA 1000VA 1500VA 2000VA Models User Installation Manual www xpcc com 2022 Xtreme Power Conversion Corporation All rights reserved Rev 7 6 22...

Page 2: ...Preparation 3 Installation 3 Hardware Installation 3 Maintenance Service and Faults 4 Storage 5 BasicOperation 5 Front and Top Panel Description 5 LCDIndicators 6 Troubleshooting 7 Fault Reference Cod...

Page 3: ...ed capacity Hardware Installation Guide 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least 8 hours is recommended to ensure that the battery s maximum char...

Page 4: ...lectric shock The battery circuit is not isolated from the input voltage Hazardous volt ages may occur between the battery terminals and the ground Before touching please verify that no voltage is pre...

Page 5: ...months in high temperature locations Basic Operation Front and Top Panel Description 1 Input Circuit Breaker The circuit breaker provides optimal overload protection 2 AC Inlet Connect to utility powe...

Page 6: ...interruptible Power Supply Definitions for Illuminated LCD Indicators LCD Indicators AC INPUT Voltage V OUTPUT Voltage V Initial Line mode Bat mode Battery capacity Load capacity Fault Sound disable P...

Page 7: ...problem Outlets do not provide power to equipment Circuit breaker is tripped due to overload Turn the UPS off and unplug at least one piece connected equipment Unplug the power cord of the UPS then p...

Page 8: ...E14 Overload Your equipment requires more power than the UPS can provide It will shutdown Shut off non essential equipment If this solves the overload problem the UPS will transfer to normal operation...

Page 9: ...tery type Sealed maintenance free lead acid Battery quantity size 1 12V 9AH 2 12V 7AH 2 12V 9AH 2 12V 9AH Charging current 1A max Typical recharge 4 hours to 90 PHYSICAL Dimensions W x D x H 17 2 x 16...

Page 10: ...sk you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorizati...

Page 11: ...ipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an...

Page 12: ...rson or entity that originally purchased the Product from an authorized reseller or distributor of XPC Products The Purchaser of this Product is protected for the term of the XPC Limited Warranty agai...

Page 13: ...Product 6 The Load Protection Policy does not apply if the Product has been operated in a failure mode or not in compliance with XPC operating instructions in the Product user s manual or if the Conne...

Page 14: ...will request that all Con nected Equipment for which a Load Protection Policy claim has been submitted be sent for evaluation to either XPC or an authorized service center If it is determined that the...

Reviews: