6
OPERATION
CFPT includes
Flow sensor:
Temperature sensor:
Salt sensor
Mark: The salt reading is /-300 ppm accuracy.
CFPT Dual Voltage 115V-230V Power Center
CFPT Power Center is a dual voltage power supply which means 115V/230V no wiring is required, The Power
Supply converts AC electrical current to a low-voltage DC electrical current which is required to produce
chlorine.
The Power Center contains the transformer, fuse ,connector to the cell and the AC electrical current wiring
configuration with the DC electrical current output cable to CFPT. A fuse is mounted in the enclosure for
additional protection. For information about installing and proper use of the Power Center, see the “CFPT
installation”
WARNING: CHLORINE GAS BUILDUP CAN OCCUR WITH IMPROPER WIRING:
To reduce the risk of personal injury, the Power Center
must be installed on and wired to the load side of the
time clock, electronically controlled switch, or relay
load side, so that it will receive power only when
the pool pump is on. Otherwise, dangerous chlorine
gas buildup can occur. The CFPT should never be
energized when the pool pump is OFF and water is
not flowing through the unit.
Ensure to Install Chlorine/Bromine Feeders after CFPTCell
When using the CFPT with an in-floor cleaning system, it is recommended that a separate return line be used
for the cleaner to reduce the increased water pressure stress on the CFPT cell.
Loop Plumbing Diagram
CFPT is designed to operate with water flow rates from 25+/-5 gallons per minutes (gpm)
up to 105 gpm. Over 80 gpm you must use a bypass loop for the best chlorine production.
Installations with flow rates over 80 gpm include those that have in-floor cleaning systems
or booster pumps. These systems must use a bypass loop with the CFPT with a flow
control valve that assures that the flow through he CFPT is maintained within its designed
operating water flow rates.
● Always install the CFPT AFTER the filter and heater. The CFPT should be at least three
(3) feet away from the heater outlet.
● If CFPT is installed on a pool/spa combination system, install (see diagram
below) BEFORE the pool/spa return valve to allow proper chlorination of both the
pool and spa and also to avoid creating gas being trapped in the pool plumbing.
● Horizontal install the CFPT cell.