Summary
To physically set up a system with one or more VM22E units, perform the following steps:
1.
Connect the first VM22E unit to the ADPRO device via the MIO card.
2.
Connect the first VM22
E unit to the ADPRO device’s audio line out.
3.
Connect the VM22E unit(s) to the necessary amplifiers and speakers.
4.
In case of multiple units in cascade: interconnect the units.
5.
Set the VM22E unit(s) address(es).
6.
Power the first VM22E unit.
2.2
Required Material
You need the following material:
Item
Included
VM22E unit (one unit per 4 required audio output channels)
Yes
12 VDC power supply
No
Cable for connecting the VM22E to the MIO card
No
Audio cable (2 x 3.5 mm jack) for connecting the VM22E to the ADPRO
device
’s audio output
Yes
Audio amplifiers and speakers
No
RCA cables (cinch) for connecting the VM22E to the amplifier
No
Flat cable for cascading units
Yes, for cascading 4 units*
(*) If you need to cascade more than 4 VM22E units, you can order an 8-socket flat cable separately. For details, see
on page 7.
Power supply specifications
:
12 VDC; min. 500 mA for cascading 8 VM22E units (60 mA per unit @ 12 VDC)
Plug: 5.5 x 2.5 mm male DC plug (0.22 x 0.098 in).
Cabling to MIO card
: standard alarm cable (min. 5 cores) is sufficient if you keep the distance between the
ADPRO device and the VM22E unit as short as possible.