Note
The XO I/O Interface USB modules function just like internal MIO/EIO Next Generation cards, but
with the following restrictions:
l
There are no AUDIO OUT and AUDIO GND ouputs: if you want to use a VM22A audio switcher,
you have to connect it to the built-in MIO card instead. It is possible to use a VM22E switcher.
l
The RS-485 PTZ setting is 2-wire. You cannot change it to 4-wire.
1.2
Possible Configurations
You can have maximum two sets of MIO/EIO cards on your XO device, built-in and external cards combined.
l
If you already have 1 MIO card built into your XO device, you can only use the single module as a secondary
set of MIO/EIO cards.
l
If you already have 2 MIO cards built into your XO device, you cannot use any modules.
Note
Because FastTrace 2 Series and iFT Series devices typically have at least one MIO card built in, only
the single module is suitable, as a second set of MIO/EIO cards. The double module is for future
applications.
You have to map the modules to the correct card set (MIO-1 or MIO-2) using the
hardware configuration tool
. If
not, the XO device will not discover the cards and you will not be able to use the inputs/outputs.
Furthermore, if you are using adapters on the USB ports of your XO device (to connect to PIR detectors or for
PTZ control of analogue cameras), you also have to map these 'devices' using the hardware configuration tool. If
the system detects a mismatch between the items configured in the hardware configuration tool and the hardware
that the system has detected (either more or less than configured), the system will activate system input 0002 –
[SYST] – HW CFG MISMATCH.
Note
Although it is technically possible to disable an existing, built-in MIO/EIO card in the hardware
configuration tool, and use an external module instead, Xtralis recommends to keep and use the built-
in cards. If you disable a built-in MIO card, you have to switch off the buzzer and watchdog features,
or the system will beep continuously. Switching off the buzzer and watchdog seriously reduces the
system's reliability and security.
1.3
System Requirements
To connect and install the XO I/O Interface USB modules, you need:
l
An XO device running firmware version XO 4.00 or above.
l
For the single module: 1 free USB port on the XO device.
l
For the double module: 2 free USB ports on the XO device.
1.4
Ordering Information
Use these reference numbers to place your order with Xtralis:
Item
Reference number
Single module: XO I/O Interface USB Module,
1 x (MIO + EIO)
49840600
Double module: XO I/O Interface USB Module,
2 x (MIO + EIO)
49840610