IP Power Manager XL-IPM401 User’s Guide
5
www.xtendlan.com
1 Specification
1.1 Working limits
¾
Maximum rated voltage: 250V AC, 24V DC
¾
Maximum rated currency: (Total) for 120V 15A, for 240V 10A
¾
Maximum rated currency: (Individual) 6A
¾
Action delay: Max 10ms
¾
Working temperature: 0 ~ 70°C
NOTE:
IP Power Manager XL-IMP401 use
power (IN)
wire at
10A current
.
Max output current (total) 10A / 240V
Max (individual) 6A
1.2 Interface Description
XL-IPM401
Front interface shown below: ]
From left to right:
1.
POWER RESET: self-protect AC reset button. IP Power XL-IPM401 can cut off the power supply of
outlets automatically if there is a shortcut o current overload. After user having solved the problem, push
the reset button, the AC power supply will become normal.
2.
4x LED indicator lights: If the LED is on, means the corresponding outlet is power on.
3.
CONSOLE: RS-232 port, provide the power output state and get IP address to re-update if update fail
4.
Cycling button: allow to switch among outlets
5.
On/off button: allow to control manually outlet selected by cycling button.
6.
NETWORK: RJ-45 connector for Ethernet