Appendix
Ⅳ
Exception Handling
Issue
Possible Reason
Solution
After power is applied,
there is no action
(self-test)
and no video image.
Cable harness is improperly
connected
Verify that the
connector input
orientation
of
the
Input power voltage is too low
Verify the voltage of the input power
Power supply does not work
Change a new power supply
Self-test is normal, but
dome
cannot
be
controlled.
Wrong communication
settings
Set the correct protocol, baud rate
and address of dome device
Improper connection of
control cable (polarity)
Verify the polarity of the RS485
connection as per the instruction
manual
Noise self-
testing
after
Mechanical obstruction
Verify and correct it
Camera
module
is
not
installed correct
Correct
Low power
Change the correct power supply
Image is not stable
Low power
Check the power supply or make sure
the power input is AC 24V
Video cable is improperly
connected.
Verify the connection of the video
cable
Image is blurring
Camera is on manual focus
Change to auto focus
The lens is dusted
Clean the lens
Controlling the dome
is not smooth
Power is too low
Change the AC 24V Power supply
Communication distance is
too long
Make sure the distance is in the
allowed range
RS485 cable is not properly
connected.
Make
the
RS485
is
properly
connected.
Too many domes connected
Make sure the connected dome is in
the allowed quantity