Appendix 2: Default X-over settings and names for all formats.
X-over
Output 1 Output 2 Output 3 Output 4 Output 5 Output 6
2x2 way+Ms
Low
High
Low
High
Msub
Aux
120Hz – 1k82Hz 1k82Hz – 22kHz 120Hz – 1k82Hz 1k82Hz – 22kHz 24.8Hz – 120Hz
<10Hz – 22kHz
2 x 3 way
Low
Mid
High
Low
Mid
High
22.1Hz – 120Hz 120Hz – 1k82Hz 1k82Hz – 22kHz 22.1Hz – 120Hz 120Hz – 1k82Hz 1k82Hz – 22kHz
4 way + 2
Low
LoMid
HiMid
High
Aux
Aux
15Hz – 149Hz 149Hz – 1k31Hz 1k31Hz – 8kHz 8kHz – 22kHz 20.1Hz – 22kHz 20.1Hz – 22kHz
5 way + 1
Sub
Low
LoMid
HiMid
High
Aux
15Hz – 80.3Hz 80.3Hz – 180Hz 180Hz – 1k31Hz 1k31Hz – 8kHz 8kHz – 22kHz 20.1Hz – 22kHz
6 way
LoSub
Sub
Low
LoMid
HiMid
High
15Hz – 80.3Hz 80.3Hz – 149Hz 149Hz – 1kHz
1kHz – 4kHz 4kHz – 10k1Hz 10k1Hz – 22kHz
Note: All filters set to 24dB Linkwitz-Riley.