22
operation
1. Refer to the “Safety Precautions” pgs. 7-12 before starting the unit.
2. Locate the Safety Decals on your unit and heed their warnings.
3. Ensure that the switch is in the “OFF” position.
4. Pointing the trigger gun in a safe direction, unlock the trigger gun and
squeeze the trigger. Brace yourself for possible gun kickback when
the pump starts.
5. Move the switch to the “Pump” position.
6. Once the unit has started, perform the following procedures with the
gun open:
a. Inspect for system water leaks, oil leaks and fuel leaks. If a fuel leak
is found, TURN UNIT OFF IMMEDIATELY! See “Risk of Explosion or
Fire”, pg. 8. Be sure that all damaged parts are replaced and that the
mechanical problems are corrected prior to operation of the unit. If you
require service, contact Customer Service.
b. Inspect high pressure hoses for kinking, cuts and leaks. If a cut or
leak is found, DO NOT TOUCH HOSE AT LEAK!!! TURN UNIT OFF
IMMEDIATELY! Replace hose before starting the unit. See “Risk of In-
jection or Severe Cutting Injury” pg. 9. Be sure that all damaged parts
are replaced and that the mechanical problems are corrected prior to
operation of the unit. If you require service, contact Customer Service.
7. At this point, the unit is operating as a cold water pressure washer.
Trigger the gun several times and try adjusting the water pressure by
rotating the grip on the lance. NEVER place hand or fingers in front of
the nozzle or look directly into the nozzle! High pressure water creates
a risk of severe injury!
8. Do not allow unit to operate in bypass mode (with trigger closed) for
more than three minutes without triggering the gun. Failure to follow
this simple rule can cause premature failure of pump packings.
9. Your pressure washer can deliver high pressure spray and a variety
of spray patterns using cold water. If you wish to use the Hot Water,
Steam application or Cleaning with Detergents, for the correct proce-
dures.
CAUTION
DO NOT ALLOW SPRAY PATTERN TO REMAIN ON A FIXED AREA
FOR AN EXTENDED PERIOD OF TIME. POSSIBLE DAMAGE MAY
OCCUR TO THE AREA.
Summary of Contents for HW152EMD
Page 1: ...operation manual HW152EMD HW204EMD ELECTRIC HOT WATER PRESSURE WASHER...
Page 36: ...36 flow chart 57 6 013 FLOW CHART parts list...
Page 38: ...38 frame assembly 59 10 Copyright 2013 FRAME ASSEMBLY parts list...
Page 40: ...40 motor pump assembly 61 12 Copyright 2013 MOTOR PUMP ASSEMBLY parts list...
Page 49: ...49 69 20 Copyright 2013 HEAT EXCHANGER BLOWER MOTOR heat exchanger blower motor parts list...
Page 51: ...51 boiler assembly 71 22 pyright 2013 BOILER ASSEMBLY parts list...
Page 62: ...62 wire schematic for hw204emd 83 34 ht 2013 WIRE SCHEMATIC FOR C204EMHW HW204EMD parts list...