20
www.XSscuba.com
XS Scuba MultiMax Breathable Inflator Service Manual
ii. Fit the purge cover (41) into the retainer ring
(42)
iii. Press into place by inserting the 4 tabs into
the 4 slots. Be sure that the XS Scuba logo is not
upside down.
b. If you took the mouthpiece (25) off, replace it
now.
c. Install hose connector assembly
i. Slide o-ring (4) on to the hose connector (3).
ii. Insert assembly into the body (8).
iii. Secure threaded collar (2) to lock into place
iv. If the hose connector (3) was removed from the
BC’s corrugated hose, then reattach it to the BC.
d. Attach MultiMax to the BC’s corrugated hose
i Insert the cable retaining pin halfway through the
hose connector (3)
ii Place loop of rapid exhaust cable over the pin
iii Engage the pin into the far wall of the hose
connector (3)
iv Push the hose over the hose connector (3)
being very careful not to let the cable retaining pin
disengage from either wall of the hose connector (3)
v. Apply a new zip-tie.