background image

© 2016 Directed. All rights reserved.

Rev.: 20160810

Platform: DBALL/DBALL2
Firmware: FORD3 Range Extender Ready (RXT) Installation

Page 8

Feature and Option List

To enter feature programming routine

-

Turn the ignition ON, then OFF. 

-

Within 5 seconds

, press and HOLD the programming button until the LED turns ON orange (after 3 seconds). Release the 

Programming button.

-

The LED will flash green once slowly to indicate the feature number is 1. After a short delay, the LED flashes red rapidly to indicate 

the current option of feature 1 (i.e. 1x green followed by 1x red indicates feature 1 is set to option 1). The flashing sequence will repeat 
until a new command is entered.

Changing feature options

-

Press the lock/arm or unlock/disarm button on aftermarket transmitter to change the option of the selected feature. 

-

The LED flashes red rapidly the number of times equal to the current option number. After a short delay, the LED flashes green slowly 

the number of times to indicate the current feature. The flashing sequence will repeat until a new command is entered.

Accessing another feature

-

Press and release the programming button a number of times to advance from the current feature to the next desired feature. 

-

The LED flashes green slowly the number of times equal to the feature number. After a short delay, the LED flashes red rapidly to 
indicate the current option of the current feature. The flashing sequence will repeat until a new command is entered.

When the maximum number of features or options is reached, the LED will start flashing again from the first feature or option.

Once a feature is programmed

-

Other features can be programmed.

-

The feature programming can be exited.

Exiting feature programming

-

No activity for 30 seconds; after 30 seconds, the LED will turn ON orange for 2 seconds to confirm the end of the programming 

sequence.
OR

-

Press and HOLD the programming button for 3 seconds. After 3 seconds, the LED will turn ON orange for 2 seconds to confirm the 

end of the programming sequence.

Feature Programming

Programming 

Button

* Default option

Feature

Operation

Flashes / Option

Description

1. Disabled*

Module is connected to a remote starter using a standard installation.

2. RFTD Output

Module is connected to an XL202 using an RSR or RXT installation (when available).

3. SmartStart

Module is connected to SmartStart using an RSR or RXT installation (when available).

1. Disabled

The OEM alarm will not be controlled by DBALL upon remote start. No disarm or arm 
command will be executed at the beginning or end of the sequence; it must be controlled by 
the Remote Starter.

2. Safelock

Smart OEM Alarm Control will behave like a standard Safelock feature on a remote starter. It 
will unlock at the beginning of the sequence, and relock after start and shutdown.

3. Enabled*

Smart OEM Alarm Control will synchronize with the OEM alarm so that it will disarm and 
rearm the vehicle in the remote start sequence, only when required. The reason for this is, 
factory alarm control must often be done by lock or unlock operation. This could create 
unnecessary actions on door lock modules, such as the horn to honk. When possible, Smart 
OEM Alarm Control will monitor the alarm and door lock status to detect if the disarm or 
rearm is required. If the vehicle is unlocked or is not equipped with factory alarm, the 
disarm/rearm will not be executed. Smart OEM Alarm Control will also monitor the remote 
starter actions so that the factory alarm control is not done twice. A remote starter, for which 
the Safelock feature is active, will work perfectly with this option and will make it invisible to 
the user.

2

Smart OEM Alarm Control

1

RF Output Type

It is recommended to configure all the features and options listed below using the configuration tool found on the module 
flashing page on www.directechs.com. The web offers more options such as RXT; however, manual configuration of the 
features is possible using the information on this page.

Summary of Contents for DBALL

Page 1: ...rence Chart SmartStart XL202 Installation Notes Programming Module Programming Module Reset Hard Reset Feature Option List Feature Programming LED Diagnostics Troubleshooting Limited One Year Consumer...

Page 2: ...wiring programming and troubleshooting for these vehicles Vehicles 2016 2015 2014 2013 2012 2011 DL Arm Factory Security DL Disarm Factory Security DL Door Lock Control DL Door Unlock DL Trunk Hatch R...

Page 3: ...t Green Black 2 Ground Black 14 12V Red 13 MS CAN High Gray Orange pin 3 Ground pin 4 MS CAN Low Violet Orange pin 11 12V Red Violet pin 16 Start Stop Switch C2195 Connector 1 5 4 2 6 3 PTS Yellow or...

Page 4: ...OBDII diagnostic connector Black 16 Ground Black Blue 4 OBDII diagnostic connector Black 16 PTS Yellow or Yellow Orange 18 C2195 Connector start stop switch Black 6 MS CAN High Gray Orange 3 Data OBD...

Page 5: ...tion Wires Gray White Connect Gray wire to Ground 5 pins D2D 4 pins white 4 pins 2 pins not used CABLE CABLE The modules must be connected in a specific order Refer to the Module Programming section f...

Page 6: ...an Internet Explorer browser version 6 or higher and go to www directechs com The detail of the platform and firmware that is currently saved on the interface module will be indicated in the top righ...

Page 7: ...n harness to the module 10 pin D2D st 1 12 pin 14 pin nd 2 th 4 rd 3 Solid Release Solid Solid Flashes Wait 3 seconds until the LED turns ON solid orange and wait 10 more seconds until the LED starts...

Page 8: ...ogramming button for 3 seconds After 3 seconds the LED will turn ON orange for 2 seconds to confirm the end of the programming sequence Feature Programming Programming Button Default option Feature Op...

Page 9: ...ramming button 5 times J1850 not detected Check the J1850 wire connection Wake up the data bus by turning the ignition on and try again CAN1 not detected Check the CAN1 Tan and Tan Black wire connecti...

Page 10: ...ived TRUNK command received AUX1 command received AUX2 command received AUX3 command received Takeover successful Normal operation Runsafe was not disabled No UNLOCK command was received prior to open...

Page 11: ...D feature is disabled Make sure RXT is selected from the web in the flashing process OEM RS disabled The factory remote start option is disabled Refer to the vehicle s owner manual to reactivate the f...

Page 12: ...R ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO ANY CONSEQUENTIAL DAMAGES INCIDENTAL DAMAGES DAMAGES FOR THE LOSS OF TIME LOSS OF EARNINGS COMMERCIAL LOSS LOSS OF ECONOMIC OPPORTUNITY AND THE LI...

Page 13: ...can be modified in some vehicles refer to your vehicle owner s manual for more information A maximum of 2 remote starts can be performed between ignition cycles Runtime Reset The Runtime Reset featur...

Reviews: