Xpresskit DBALL Installation Manual Download Page 6

© 2016 Directed. All rights reserved.

Rev.: 20160810

Platform: DBALL/DBALL2
Firmware: FORD3 Range Extender Ready (RXT) Installation

Flashes

Press 5 times on the programming button. 
The LED flashes orange.

&

Press x5

Module Programming

Page 6

2

Make sure the key is inside the vehicle.

Key Inside 

the Vehicle

4

&

Press x2

ENGINE

START

STOP

Do NOT

press the 

brake pedal

Press the Push-to-Start (PTS) button twice to turn the ignition ON.

Important: 

Do NOT depress the brake pedal.

3

Go to the next page to complete the module programming.

Refer to the LED Diagnostics section on page 9 for more information and for troubleshooting purposes.

Important

Make all the required connections to the vehicle, as described in the wiring diagram(s) found in this guide, and double check to 
ensure everything is correct prior to moving onto the next step.

Note: 

Before connecting either the XL202 or SmartStart module to DBALL, it is important to ensure that the proper feature and 

function programming is selected using XpressVIP (version 4.5 or higher). Visit www.directechs.com to download the latest 
version of the application.

Warning! 

To take advantage of advanced features, you must use XpressVIP 4.5 or higher. Using version 2.9 or 3.1 will limit 

available functions and features.

1. Connect the interface module to your computer using the 

XKLoader

.

2. Open an Internet Explorer browser (version 6 or higher), and go to www.directechs.com. The detail of the platform and firmware 

that is currently saved on the interface module will be indicated in the top right corner of the page.

3. Select the 

year

make

 and 

model

 of the vehicle; the page will refresh to display the compatible firmware. 

4. In the search result page, select 

Config for RXT

, and follow the instructions provided on the screen.

5. Once you have configured your options, click on the 

FLASH 

button to upload the firmware onto the interface module.

6. The following message will be displayed when the upload is completed: 

“The flashing is successfully completed. You may now unplug the kit.”
You can now proceed with the programming instructions below.

1

10-pin

D2D

st

1

12-pin

14-pin

nd

2

rd

3

&

Solid

 Connect the 10-pin, 12-pin and 14-pin harnesses to 
DBALL, then wait until the LED turns ON solid red.

10-pin

D2D

XL202

10-pin

D2D

SmartStart

OR

The DBALL module 

must 

be disconnected from any power source before SmartStart can 

be connected to it. Failing to do so could damage DBALL.

a.

  To ensure that the D2D communication between SmartStart and DBALL works properly, the 

Gray wire must be connected to a ground source (

Rev B 

SmartStart), and the Brown or Blue 

loop must be cut (

Rev A 

SmartStart).

b.

  Do 

NOT 

connect the 2-pin harness (on SmartStart). Power and ground will be provided by 

the DBALL D2D connector.

Connect SmartStart to DBALL using the D2D port.

SmartStart Installation

Connect XL202 to DBALL using the D2D port.

XL202 Installation

Summary of Contents for DBALL

Page 1: ...rence Chart SmartStart XL202 Installation Notes Programming Module Programming Module Reset Hard Reset Feature Option List Feature Programming LED Diagnostics Troubleshooting Limited One Year Consumer...

Page 2: ...wiring programming and troubleshooting for these vehicles Vehicles 2016 2015 2014 2013 2012 2011 DL Arm Factory Security DL Disarm Factory Security DL Door Lock Control DL Door Unlock DL Trunk Hatch R...

Page 3: ...t Green Black 2 Ground Black 14 12V Red 13 MS CAN High Gray Orange pin 3 Ground pin 4 MS CAN Low Violet Orange pin 11 12V Red Violet pin 16 Start Stop Switch C2195 Connector 1 5 4 2 6 3 PTS Yellow or...

Page 4: ...OBDII diagnostic connector Black 16 Ground Black Blue 4 OBDII diagnostic connector Black 16 PTS Yellow or Yellow Orange 18 C2195 Connector start stop switch Black 6 MS CAN High Gray Orange 3 Data OBD...

Page 5: ...tion Wires Gray White Connect Gray wire to Ground 5 pins D2D 4 pins white 4 pins 2 pins not used CABLE CABLE The modules must be connected in a specific order Refer to the Module Programming section f...

Page 6: ...an Internet Explorer browser version 6 or higher and go to www directechs com The detail of the platform and firmware that is currently saved on the interface module will be indicated in the top righ...

Page 7: ...n harness to the module 10 pin D2D st 1 12 pin 14 pin nd 2 th 4 rd 3 Solid Release Solid Solid Flashes Wait 3 seconds until the LED turns ON solid orange and wait 10 more seconds until the LED starts...

Page 8: ...ogramming button for 3 seconds After 3 seconds the LED will turn ON orange for 2 seconds to confirm the end of the programming sequence Feature Programming Programming Button Default option Feature Op...

Page 9: ...ramming button 5 times J1850 not detected Check the J1850 wire connection Wake up the data bus by turning the ignition on and try again CAN1 not detected Check the CAN1 Tan and Tan Black wire connecti...

Page 10: ...ived TRUNK command received AUX1 command received AUX2 command received AUX3 command received Takeover successful Normal operation Runsafe was not disabled No UNLOCK command was received prior to open...

Page 11: ...D feature is disabled Make sure RXT is selected from the web in the flashing process OEM RS disabled The factory remote start option is disabled Refer to the vehicle s owner manual to reactivate the f...

Page 12: ...R ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO ANY CONSEQUENTIAL DAMAGES INCIDENTAL DAMAGES DAMAGES FOR THE LOSS OF TIME LOSS OF EARNINGS COMMERCIAL LOSS LOSS OF ECONOMIC OPPORTUNITY AND THE LI...

Page 13: ...can be modified in some vehicles refer to your vehicle owner s manual for more information A maximum of 2 remote starts can be performed between ignition cycles Runtime Reset The Runtime Reset featur...

Reviews: