background image

XpressFill

XF4100 / XF2100

Summary of Contents for XF4100

Page 1: ...XpressFill XF4100 XF2100...

Page 2: ......

Page 3: ...r death Do not use the machine in any way not covered in this manual or for any purpose other than those explained in the following pages Severe product damage and or injury could result from the use...

Page 4: ...Safety Warnings...

Page 5: ...Guarantee We guarantee our products to be free of defects in materials and workmanship The filler will be repaired or replaced if upon inspection at the factory the filler is found to be defective in...

Page 6: ...es the filler can be cleaned by the customer 265 Prado Road Suite 1 San Luis Obispo CA 93401 805 541 0100 xpressfill com sales xpressfill com 6 XpressFill Systems LLC Unscrew the adjustable knobs hold...

Page 7: ...as option The green light will take a few seconds to illuminate as the purge cycles operates without gas connected While holding the shelf loosen the adjustable knobs on either side so the shelf moves...

Page 8: ...ere is minimal air in the flow path turn the inline strainer upside down while the pump is running with four bottles in place This ensures that the air bubbles in the strainer housing mostly dissolve...

Page 9: ...cle Variable Flow Control The four white valves on top of your unit are for flow control Each valve controls the spout in which it is aligned The valves functions are to increase or decrease flow per...

Page 10: ...does not start it is typically a case of moisture between the spout and sensor tube This can corrected by drying the entire area with a dry cloth or towel in between the two stainless steel sprouts a...

Page 11: ...s When using PBW in food processing areas the equipment that has been cleaned must be rinsed with potable water After cleaning with PBW the manufacturer recommends sanitizing prior to the next use San...

Page 12: ...tting and pulling lightly to check that the connection is secure Removal requires using the collet release tool to firmly push the collet and remove the tube A tool is included with the filler and can...

Page 13: ...g filling Spares are offered and located inside the filler Spare Fuse There is a spare fuse in the power cord receptacle Unplug the machine and set a screwdriver on the notch do not remove screws and...

Page 14: ...l assembly Remove the coil assembly off the center shaft Unscrew the shaft from the stainless steel base It is not necessary to unscrew the tubing adaptors from the stainless steel base Now rinse out...

Page 15: ...265 Prado Road Suite 1 San Luis Obispo CA 93401 805 541 0100 xpressfill com sales xpressfill com 15 XpressFill Systems LLC Delay Timer Adjustment Accessory Kit...

Reviews: