Gas Sparge
If your filler has the gas sparge option, first make sure you have the hose going into the filler safely connected to
your gas tank and regulator. The barb fitting on your unit is ¼″, use ¼″ tubing, braided for strength, and good hose
clamps. The recommended pressure is 20-30 psi. The gas purge is automatic, it will purge the bottle once the bottle
is placed on the shelf, then it will start the liquid filling cycle.
Variable Flow Control
The four white valves on top of your unit are for flow control. Each valve controls the spout in which it is aligned.
The valves functions are to increase or decrease flow per spout. Usually if foaming is occurring in your product,
decreasing flow and or slowing down your flow will eliminate this problem.
To Decrease flow: Turn the knob Clockwise until desired flow is achieved.
To Increase flow: Turn the knob Counterclockwise until desired flow is achieved
.
265 Prado Road, Suite 1 | San Luis Obispo, CA 93401 | 805.541.0100 | xpressfill.com | [email protected]
9
| XpressFill Systems LLC
3
Options