1.0 INTRODUCTION

2.0 M

D

OUNTING AND ISMOUNTING

3.0 SPECIFICATIONS

4.0 A

D

PPLICATION

IAGRAM

5.0 WIRING

6.0 R

S

T

ECOMMENDED WIPING ECHNIQUE

6.1 Tapping the sensor

6.2 Scrolling the sensor up and down

7.0 INDICATION

8.0 Q

P

UICK ROGRAMMING

8.1

Adding Master Finger and delete all users

8.2

Add User In Group 1

8.3

Add User In Group 2

8.4 Delete user

8.5

Delete All Users in Group 1

8.6

Delete All Users in Group 2

9.0

P

-  B

EA

R

R

U

AIRING

IOMETRIC R

DER AND EMOTE ELAY

NIT

9.1

Pairing B100PAD-SA with DINRTT

9.2

Pairing B100PAD-SA with RTT

10.0 K

D

U

EEP THE OOR

NLOCK

11.0 P

B100PAD-SA

K

ROGRAMING

WITH EYPAD

11.1 Adding Users

11.2

Delete User By User Location Number

11.3

Delete User Group

11.4

Delete All Users

11.5

Delete User by User Finger

11.6

Set Door Relay Time

11.7

Buzzer Settings

11.8 Backlight Settings

11.9

Set the Touch Button Function

11.10 Unpair Remote Relay

11.11

Entry Mode Settings

11.12

Add Administrator

11.13

Delete Administrator

11.14 Reset to defaults

11.15 Double Swipe Unlocks Door

3

3

3

4

5

6

6

6

6

7

7

8

8

8

8

8

9

9

9

9

10

10

11

11

12

12

13

14

15

16

16

17

18

18

19

19

Contents

..............................................................

..................................................

..............................................................

.....................................................

.........................................................................

...........................................

............................................................

.................................................

....................................................................

....................................................

.........................................

...........................................................

.........................................................

...................................................

..............................

...........................................................

.................................................

.....................................................................

...................................................................

.............................................................

...............................................................

.............................................................

.........................................................................

...........................................................

................................................................

...........................................................

...............................................................

.......................................................
.......................................................

.................................................

.............................................................

.................................................

...........................................................
...........................................................
...........................................................

...........................................................

19

www.xprgroup.com

11.14 Reset to defaults

11.0 P

B100PAD-SA

K

ROGRAMING

WITH

EYPAD

1.

Press

3,6.

2.

Press

.

9,1,4,7

3.

Press

to confirm

A

To Exit press 0, A

11.15 Double Swipe Unlocks Door

1.

Press

3,3.

To Exit press 0, A

2.

Double Swipe

Select the

from the table

Double swipe Unlocks Door

1

Enable

2

Disable

3.

Press

to confirm.

A

Note:
Refer to Chapter 10 for this feature

Note:
Does not affect the fingerprints  stored and the pairing

product ver. 1.0.2.0.0

product ver. 1.0.2.0.0

Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.

BL

BL

BL

BL

ADMIN PIN or

x 5

Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.

BL

BL

BL

BL

ADMIN PIN or

x 5

Summary of Contents for B100PAD-SA

Page 1: ...requirements of EMC directive 2014 30 EU In addition it complies with RoHS directive EN50581 2012 Visual Plus Corporation s a Dr ve Richelle 161 WOP G Bte 34 1410 Waterloo Belgium www xprgroup com B10...

Page 2: ...ttings 11 8 Backlight Settings 11 9 Set the Touch Button Function 11 10 Unpair Remote Relay 11 11 Entry Mode Settings 11 12 Add Administrator 11 13 Delete Administrator 11 14 Reset to defaults 11 15 D...

Page 3: ...sed on the processor The system is capable of detecting and defeatingwell knownfakefingermechanisms suchasmolded gummy fingers The coating on the surface of the TouchChip sensor provides protection fr...

Page 4: ...OFF Finger Finger or and PIN code By scrolling and tapping on the sensor or by keypad 1 Master and 2 Admin Fingers Up to 508 DPI Yes Yes via converter and windows application R 485 S 150 mA max 9 14...

Page 5: ...u on Func on in the remote relay Unit Swipe Master Admin nger or enter Admin PIN The Biometric reader starts to blink BL BL BL BL ADMIN PIN or x 5 5 0 WIRING NC COM NO Tamp Blue Yellow Red Black Pink...

Page 6: ...m a command Enter and con rm 6 2 Scrolling the sensor up and down Scroll the sensor DOWN to navigate the programming menu Scroll the sensor UP to exit the programming menu Navigate the Programming Men...

Page 7: ...he Administrator but the Administrator can not delete the Master 3 The User can be assigned to one of the 8 available User Groups With the Quick programming feature the Users are assigned in Group 1 o...

Page 8: ...the Card then swipe the nger min Finger Or And Card 6 mes When using keypad for mode rst enter the PIN Code then swipe the nger min Finger Or And Pin Code 6 mes When using Mifare card reader for Mode...

Page 9: ...INRTT 12V 12V GND GND G N D P 1 B N 1 O COM 1 2 9 2 Pairing B100PAD SA with RTT 1 Put Dipswitch No 1 to posi on ON RTT beeps con nuously and the red led blinks 2 Put Dipswitch No 1 to posi on OFF 3 Wa...

Page 10: ...to step 1 To Exit press 0 A x 6 Swipe Master Admin nger or enter Admin PIN The Biometric reader starts to blink BL BL ADMIN PIN or x 5 Op onal Note The user is automa cally assigned to Relay1 and gro...

Reviews: