1. Connect the devices according to the connec on diagram above.
2. Use the diodes provided when the door lock is DC powered or the capacitor with 10K resistor when the lock is AC powered.
3. Use the Dipswitch pin1 for RS485 tuning.
4. Insert the ba ery provided with the hardware kit.
5. Connect the power.
INSTALLATION
RS485 TUNING
IMPORTANT NOTE:
- The RS485 Communication Line must be made in daisy chain, NOT in a star type configuration.
- The cable must be twisted and shielded. Connect the EARTH to the shield.
- Connect the COM to each unit in the RS 485 line.
- Terminate both ends of the line with 120 Ohm resistor. If end of line is EWS-DR, use built in resistor (120 ohm) by turning the Dipswitch pin1 ON.
1 km max / 32 Units (EWS and Biometric Readers)
Put the Dipswitch pin1 in ON position, on the first and last controller
in the RS 485 network, to set 120ohm resistance
between terminal pins A and B.
BIOC3
B100
com
com
com
com
CHANGING THE IP ADDRESS OF EWS(i)-DR
With PROS CS:
The default IP of the controller is
192.168.1.100
To change the IP of the EWS controller:
1. Connect the EWS controller directly to the PC.
2. Change the IP of your PC to 192.168.1.200
3. Go in the So ware and in the hardware window,
right click
on the
Portals
item, then select
Search Network Portals
. When the
Search portals
window is opened, hit
Search
.
4.Click on the “Setup” bu on.
Setup Portal
window is opened, and now you can set values for the parameters in the portal setup. Further you have the parameters of the setup explained.
PROS Software
Switch, Router
TCP/IP
max. 90m.
RS 485
TCP/IP
RS485 -
USB
Converter
RS 485
COMMUNICATION
MOUNTING
Т
HE PCB
87mm
74mm
140mm
175mm
71mm
PCB can be mounted directly on the panel. In this case, use provided
spacers for fixing and printed screen for protec on.
Use nylon spacers only,
for these holes.
7mm
15mm
PCB
Mask
43mm
43mm