Power Supply:                 

 

  

   

    12VDC

User/Event capacity:               1000/30000, 4000/24000, 8000/16000, 12000/8000 or 15000/2500, configurable by so ware
Communica on:                  

 

    

EWS-DR -RS485, EWSi-DR -RS485 and TCP/IP

Door relays:                         

  

    2 (250 VAC, 10A)

Programmable Outputs:         2 (250 VAC, 10A)
Readers:                            

    

   

 

 2

Programmable Inputs:      

    

   2, optocoupled, ON level 5-30VDC (3-28mA)

Door sensors:                    

   

     2

Exit Bu on Inputs:                 

  

2

Wiegand interface:             

   

  Programmable (8 to 128bit), 32databits, 4 parity bits

Environment temperature:  

   

0 - 45 C

Humidity:                        

        

 

   

0-80 %, non condensing

Consump on:                         

  

EWS-DR 200mA, EWSi-DR 250mA (without readers)

Fuse protec on:                       1A thermal fuse for total consump on of the controller and readers.

+

-

Power

Supply

12V out

-

-

1N4007

Electro Magnetic Lock

+

-

Lock

Power

Supply

1N4007

Electric Door Strike

(DC powered)

+

-

+

-

DC

Electric Door Strike

(AC powered)

C

R

10K

470

N

F

AC

POWER

12 VDC

TAMPER

I/O

COM

N

O

T

 F

O

R

 P

oE!

READER 2

OUTPUT 1    

  DOOR 2

DOOR SENS

& EGRESS 1

+

-

12V

C

O

M

T

C

P

U

D

P

D1  D2  O1 O2

T

X

R

X

SY

S 1

SY

S 2

Fingerprint

reader

Door Sensor

(NC, mechanical or 

relay dry contact)

Exit Button

(NO, mechanical or 

relay dry contact)

Default IP:

 192.168.1.100 

port:

 4001

+

-

5 - 30V

Reset IP

 

(press and hold for 3sec 

to reset the IP, the port 

and the network password)

Battery

(CR2032)

Card reader

Green

Orange

Black

Red

White

Yellow

Violet

Pink

For 

I/O0408

relay board   

Green

Orange

Black

Red

White

Yellow

READER 1

DOOR SENS

& EGRESS 2

DOOR 1

OUTPUT 2

INPUT 1

INPUT 2

TCP/IP

RS485

DIPSWITCH

pin

1

:

for termination 

of the RS485 cable

on the terminal 

block pins A and B

pin2:

for termination

of the I/O COM port

on the terminal block

pins

EARTH- fixing holes for
earth connection

12V

COM
TCP
UDP

SYS2

SYS1

RX

TX

D1

D2

O1

O2

Transmit/Receive

SYSTEM OK (Heartbeat)

Ethernet

Power supply

Communication

DOOR 1/2 OUTPUT 1/2

Schematic of the EWS-DR

input optocoupler

IN1+

+

GND

IN1-

IN2+

IN2-

1k

EWS-DR

+

GND

IN1+

+

T

D1

D0

LED2

LED1

PB1

DS1

D1

D0

PB2

DS2

GND

GND

GND

GND

GND

GND

12V

12V

12V

IN1-

IN2+

IN2-

LED1
LED2

COM

COM

COM

COM

NC4

NC2

T2

T1

NC3

NC1

B

B

A

A

NO4

NO2

NO3

NO1

Com

Com

IP

Reset

TCP

netw

ork

62mm

91mm

161mm

EN

Reviews: