background image

English - 9

User Maintenance Instructions

Frequent maintenance is recommended on this appliance. Failure to follow the 

maintenance instructions may cause failure of the appliance and void the warranty.

Before performing any maintenance or cleaning, always disconnect the Air Scrubber from 

its power source.

Transportation

Machine Maintenance

• 

When not in use, unplug, remove all the extension and cover the intake with the foam 

cover* (

See Also Page 7: Foam Cover

). Store the appliance in a dry and cool indoor 

place. Make sure it’s out of reach of children.

• 

Use a damp cloth to wipe the surface of the housing. Do not clean the unit with water 

directly.

• 

Check if the grille covers are clean. Remove dirt or any other objects that could block 

the air inlet and air outlet.

• 

Do not stack more than five units of this appliance.

*  For model X-2480A/X-3400A only.

Handle

Carry with Handle

Lift the Air Scrubber with the 

handle on the top of the housing.

Stack in Carrier

You can stack up to 5 Air Scrubbers 

and transport.

Summary of Contents for X-3000 Series

Page 1: ...Air Scrubber Owner s Manual Model X 2000 Series X 3000 Series 115V 60HZ Read and save these instructions before use www xpower com 1 855 855 8868 info xpower com Index NA 1 A7 Edition 1 3 Final...

Page 2: ...table for use with solid state speed control Do not touch this appliance or the plug with wet hands or while standing in water Do not operate the appliance in any pooled water Do not use the product i...

Page 3: ...unidad Lire et conserver ces instructions avant utilisation www xpower com 1 855 8868 info xpower com Index NA 1 A2 Edition 1 0 Alpha Owner s Manual x 1 Air Scrubber x 1 1 Rubber Feet 2 Latch Kit 3 Co...

Page 4: ...cifications If your product s is not listed above please visit www xpower com for more information Nylon Mesh Filter Carbon Filter HEPA Filter Washable Filter Outer Nylon Mesh Filter NFR9 NFR12 NFS13...

Page 5: ...circulation inside your working area You may achieve this with XPOWER Air Mover combinations Environment Humidity For optimal efficiency and higher filter lifespan the Air Scrubber should not be opera...

Page 6: ...ne and remove the outer nylon mesh filter and foam cover Attach the ducting hose to the intake For model X 2380 X 2580 X 3380 X 3580 only For model X 2480A X 3400A only Exhaust Ducting Turn off the ma...

Page 7: ...has diminished You should clean or replace the filters See Page 10 Filter Maintenance Variable Speed Control For Model X 3400A only Turn to OFF position to switch the Air Scrubber OFF Turn to any spee...

Page 8: ...al receptacle Once a ground fault occurs the GFCI will immediately interrupt the power connection to the additional electrical receptacle Consult the Troubleshooting Guide A ground fault is an inadver...

Page 9: ...e intake with the foam cover See Also Page 7 Foam Cover Store the appliance in a dry and cool indoor place Make sure it s out of reach of children Use a damp cloth to wipe the surface of the housing D...

Page 10: ...lease follow the instructions below Continued Machine Maintenance Continued Outer Nylon Mesh Filter Organize the Cord Wrap the power cord around the intake for storage after use Use convenient clip at...

Page 11: ...p remove various substance absorbed in the carbon with an appropriate temperature If filter change light still illuminates or a decline of effectiveness is noted you might need to replace the filter H...

Page 12: ...check the installation sequence WARNING Disposal of filters No longer in use The particles captured by a used filter can cause adverse human health effects and contaminate the nearby environment once...

Page 13: ...be loaded with EVA side facing the machine housing The EVA sealing pad ensures that all the air is filtered Tips On one of the side of each filter there is a label with an arrow showing the airflow di...

Page 14: ...ps Remove all appliances on the additional electrical receptacle and press circuit reset button Unit runs but no or very low air movement Air outlet is blocked Remove blockage Filters are fully loaded...

Page 15: ...English 15...

Page 16: ...nal Electrical Receptacle N A 2 Normal Outlets N A 2 GFCI Outlets N A Cord Length 13 ft 4 m Unit Dimension L x W x H 16 6 x 10 4 x 18 9 in 42 2 x 26 4 x 48 cm 19 6 x 12 3 x 21 6 in 49 8 x 31 2 x 54 9...

Page 17: ...n for fine dust PF16 16 x 16 in 0 8 in CF15 Carbon Filter 13 x 13 in 0 6 in Filtration for gases CF35 16 x 16 in 1 4 in WF35 Washable Filter 13 x 13 in 1 3 in Medium filtration for fine dust and parti...

Page 18: ...ssistance from XPOWER please 1 Email info xpower com 2 Call XPOWER U S Customer Service Department at 855 855 8868 or other numbers provided on www xpower com 3 Visit XPOWER U S Head Office at 240 Cla...

Page 19: ...the address provided by XPOWER with the RMA number on the shipping label or the packaging 3 Include all the original parts and components XPOWER will inspect assess and advise the repairs needed and...

Page 20: ...Read and save these instructions before use www xpower com 1 855 855 8868 info xpower com 240 Clary Avenue San Gabriel CA 91776 USA Index NA 1 A7 Edition 1 3 Final XPOWER Manufacture INC...

Reviews: