background image

English - 4

Machine (Continued)

Filters

* For model X-2480A/X-3400A only.

** Additional electrical receptacle function does not apply to all models mentioned in

this manual (

See Page 14: Technical Specifications

).

The graph only presents the appearance of the filters. The actual sizes of filters with 

different part number could be slightly different. (

See Page 15: Technical Specifications

)

If your product(s) is not listed above, please visit www.xpower.com for more information.

Nylon Mesh

Filter

Carbon

Filter

HEPA

Filter

Washable

Filter

Outer Nylon

Mesh Filter

NFR9/

NFR12

NFS13/

NFS16

PF13/

PF16

CF15/

CF35

HEPA35/

HEPA35-33/HEPA50

WF35/WF35+EVA/

WF50

Outer Nylon

Mesh Filter

MODEL NUMBER

X-2380

X-2480A

X-2580

X-3380

X-3400A

X-3580

First Stage Filter

NFR9

NFS13

NFR9

NFR12

NFS16

NFR12

Second Stage 

Filter

NFS13

PF13

NFS13

NFS16

PF16

NFS16

Third Stage Filter

WF50

HEPA

35-33

CF15

WF35

HEPA

50

CF35

Fourth Stage 

Filter

-

-

HEPA

35-33

WF35

+EVA

-

HEPA

35

Summary of Contents for X-3000 Series

Page 1: ...Air Scrubber Owner s Manual Model X 2000 Series X 3000 Series 115V 60HZ Read and save these instructions before use www xpower com 1 855 855 8868 info xpower com Index NA 1 A7 Edition 1 3 Final...

Page 2: ...table for use with solid state speed control Do not touch this appliance or the plug with wet hands or while standing in water Do not operate the appliance in any pooled water Do not use the product i...

Page 3: ...unidad Lire et conserver ces instructions avant utilisation www xpower com 1 855 8868 info xpower com Index NA 1 A2 Edition 1 0 Alpha Owner s Manual x 1 Air Scrubber x 1 1 Rubber Feet 2 Latch Kit 3 Co...

Page 4: ...cifications If your product s is not listed above please visit www xpower com for more information Nylon Mesh Filter Carbon Filter HEPA Filter Washable Filter Outer Nylon Mesh Filter NFR9 NFR12 NFS13...

Page 5: ...circulation inside your working area You may achieve this with XPOWER Air Mover combinations Environment Humidity For optimal efficiency and higher filter lifespan the Air Scrubber should not be opera...

Page 6: ...ne and remove the outer nylon mesh filter and foam cover Attach the ducting hose to the intake For model X 2380 X 2580 X 3380 X 3580 only For model X 2480A X 3400A only Exhaust Ducting Turn off the ma...

Page 7: ...has diminished You should clean or replace the filters See Page 10 Filter Maintenance Variable Speed Control For Model X 3400A only Turn to OFF position to switch the Air Scrubber OFF Turn to any spee...

Page 8: ...al receptacle Once a ground fault occurs the GFCI will immediately interrupt the power connection to the additional electrical receptacle Consult the Troubleshooting Guide A ground fault is an inadver...

Page 9: ...e intake with the foam cover See Also Page 7 Foam Cover Store the appliance in a dry and cool indoor place Make sure it s out of reach of children Use a damp cloth to wipe the surface of the housing D...

Page 10: ...lease follow the instructions below Continued Machine Maintenance Continued Outer Nylon Mesh Filter Organize the Cord Wrap the power cord around the intake for storage after use Use convenient clip at...

Page 11: ...p remove various substance absorbed in the carbon with an appropriate temperature If filter change light still illuminates or a decline of effectiveness is noted you might need to replace the filter H...

Page 12: ...check the installation sequence WARNING Disposal of filters No longer in use The particles captured by a used filter can cause adverse human health effects and contaminate the nearby environment once...

Page 13: ...be loaded with EVA side facing the machine housing The EVA sealing pad ensures that all the air is filtered Tips On one of the side of each filter there is a label with an arrow showing the airflow di...

Page 14: ...ps Remove all appliances on the additional electrical receptacle and press circuit reset button Unit runs but no or very low air movement Air outlet is blocked Remove blockage Filters are fully loaded...

Page 15: ...English 15...

Page 16: ...nal Electrical Receptacle N A 2 Normal Outlets N A 2 GFCI Outlets N A Cord Length 13 ft 4 m Unit Dimension L x W x H 16 6 x 10 4 x 18 9 in 42 2 x 26 4 x 48 cm 19 6 x 12 3 x 21 6 in 49 8 x 31 2 x 54 9...

Page 17: ...n for fine dust PF16 16 x 16 in 0 8 in CF15 Carbon Filter 13 x 13 in 0 6 in Filtration for gases CF35 16 x 16 in 1 4 in WF35 Washable Filter 13 x 13 in 1 3 in Medium filtration for fine dust and parti...

Page 18: ...ssistance from XPOWER please 1 Email info xpower com 2 Call XPOWER U S Customer Service Department at 855 855 8868 or other numbers provided on www xpower com 3 Visit XPOWER U S Head Office at 240 Cla...

Page 19: ...the address provided by XPOWER with the RMA number on the shipping label or the packaging 3 Include all the original parts and components XPOWER will inspect assess and advise the repairs needed and...

Page 20: ...Read and save these instructions before use www xpower com 1 855 855 8868 info xpower com 240 Clary Avenue San Gabriel CA 91776 USA Index NA 1 A7 Edition 1 3 Final XPOWER Manufacture INC...

Reviews: