Adding oil
Make sure that the jack is on a level ground and with the head fully lowered, remove the breather valve.
The oil level should be visible at the breather valve opening approximately 12
mm below the valve open-
ing. Do not overfill! If the oil level is low, top up as required and close the breather valve.
Cleaning
The jack should only be wiped with a soft cloth. Do not use gasoline, solvents, or abrasive cleaners, as
these may damage the hydraulic seals.
Storage
Before storing, turn the handle counter-clockwise 1½
turns to release pressure in the hydraulic cylinder.
Leave the handle in this position. Store the jack on a flat surface, in a clean and dry environment, pref-
erably indoors. Make sure that the jack is protected from moisture.