Ensure the cable is securely fitted inside the entire length of the labyrinth.

If you are using the cable clamp ensure the cable is an appropriate diameter to ensure a firm grip is achieved.

Commissioning and speed controlling the Xplus2 EC RFH System:

WARNING:  THE  FAN  AND  ANCILLARY  CONTROL  EQUIPMENT 

MUST BE  ISOLATED  FROM  THE  POWER  SUPPLY  DURING 

INSTALATION OR MAINTENANCE.

Step  7 – Align the  PCB termination  Plug  with 

the PCB termination socket

Step  8 – Firmly  connect the two 

sides of the plug

Step  9  – Use  the  appropriate  method 
to  fix  the  cable  by  either  routing  the 
cable through  the  labyrinth  (as shown) 
or  fixing  into  position  with  the  cable 
clamp.

[5]

If installing  in  a  room  containing  a  fuel burning device,  it’s the installer’s  responsibility  to  ensure  that there  is 
adequate replacement air to prevent fumes being drawn down the flue when the fan is operating.

Exhaust  air  must  not  be  discharged  into  the  flue  used  for  exhausting  fumes  from  appliances  supplied  with 
energy  other  than  electricity.  Requirements  of  all  authorities  concerned  must  be  observed  for  exhaust 
discharge.

The inlet grilles should be situated at least 5.0 metres distance from the discharge outlet of a flued heating or 
cooking appliance.

For guidance on installation please refer to Xpelair’s online installation guide. 

Position of the discharge grille atmosphere:

At least 2.0 meters away from open door or window, or the inlet of another ventilation device.

The fan must always be firmly fixed, ensure the Xplus2 EC RFH unit is installed by either of the two methods 
listed below:

Using suitable wood screws fixed through the corner of the ventilator box
Using threaded bolts ≤5mm with a head size ≥8mm

Connecting the Spigots and Ducting 

Select the spigot required to suit the ventilation requirements: 
(€125mm spigot or blanking cover)

Place  a  worm  drive  clip  or  cable  tie  over  the  flexible  duct  (not 
supplied).

Fix  the flexible ducting to the spigot by tightening the worm drive 
clip or cable tie (not provided).

Align the four locating tabs on the spigot and insert the spigot into 
the unit.

Once  the  spigot  is  flush  with  the  unit  turn  the  spigot  clockwise 
until it locks firmly into position (approximately 30 degrees)

Using  the  one  of  the  screws  provided  lock  the  spigot  into  place 

and gently tighten the worm drive to create a good seal.

If  an  extract  spigot(s)  is  not  required  they  should  be  blanked  off 
with  one  of  the blanking  covers  provided.  The  blanking  cover 
should be fixed into position with a locking screw provided.

Summary of Contents for Xplus2 EC RFH

Page 1: ...osed of or delivered by Redring Xpelair Group Limited and a delivery charge made EXCLUSIONS This guarantee does not cover damage or defects arising from poor or incorrect installation improper use or lack of maintenance It is the responsibility of the installer to check that the installation parameters meet the requirements of the product and any relevant regulations If we are called out to a faul...

Page 2: ...s2 EC RFH system is designed to operate with the Xplus 2 EC RFH switch supplied The fan can be set to run in one of 4 modes Night time speed setting where the fan provides background trickle ventilation the fan could also be set to run at this speed if the house is not fully occupied Day time speed setting where the fan provides normal running conditions Timed boost speed setting where the fan wil...

Page 3: ...ts very little dirt However it may be advisable to have the unit inspected by your installer annually and clean if necessary Making sure that water does not get into the motor or electrical termination box CE Conformity This unit meets all relevant CE standards Characteristics The electric motor and fan are enclosed in the ventilator casing Attached to the casing is up to 6 125mm extract spigots o...

Page 4: ...ertically upwards only 9 The Xplus2 EC RFH has infinite speed control this will enable you to control the air flow of your Xplus2 EC RFH to your specific systems requirements while maximising the Xplus2 EC RFH s energy efficiency Step 10 Switch off the mains electrical supply and remove all fuses before commencing Step 11 Identify the correct speed controller for the speed you wish to adjust Step ...

Page 5: ...ce from the discharge outlet of a flued heating or cooking appliance For guidance on installation please refer to Xpelair s online installation guide Position of the discharge grille atmosphere At least 2 0 meters away from open door or window or the inlet of another ventilation device The fan must always be firmly fixed ensure the Xplus2 EC RFH unit is installed by either of the two methods liste...

Page 6: ...ouble insulated cable used with a cable cores greater than 0 75mm 2 which has been appropriately specified for this specific application by a qualified professional WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING INSTALATION OR MAINTENANCE 7 If you have any queries regarding the installation of this product please call the Technical Hotline 44 0 8709 0...

Reviews: