![Xpelair Xplus2 EC RFH Manual Download Page 5](http://html1.mh-extra.com/html/xpelair/xplus2-ec-rfh/xplus2-ec-rfh_manual_3596059005.webp)
[8]
Ensure the cable is securely fitted inside the entire length of the labyrinth.
If you are using the cable clamp ensure the cable is an appropriate diameter to ensure a firm grip is achieved.
Commissioning and speed controlling the Xplus2 EC RFH System:
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT
MUST BE ISOLATED FROM THE POWER SUPPLY DURING
INSTALATION OR MAINTENANCE.
Step 7 – Align the PCB termination Plug with
the PCB termination socket
Step 8 – Firmly connect the two
sides of the plug
Step 9 – Use the appropriate method
to fix the cable by either routing the
cable through the labyrinth (as shown)
or fixing into position with the cable
clamp.
[5]
If installing in a room containing a fuel burning device, it’s the installer’s responsibility to ensure that there is
adequate replacement air to prevent fumes being drawn down the flue when the fan is operating.
Exhaust air must not be discharged into the flue used for exhausting fumes from appliances supplied with
energy other than electricity. Requirements of all authorities concerned must be observed for exhaust
discharge.
The inlet grilles should be situated at least 5.0 metres distance from the discharge outlet of a flued heating or
cooking appliance.
For guidance on installation please refer to Xpelair’s online installation guide.
Position of the discharge grille atmosphere:
At least 2.0 meters away from open door or window, or the inlet of another ventilation device.
The fan must always be firmly fixed, ensure the Xplus2 EC RFH unit is installed by either of the two methods
listed below:
Using suitable wood screws fixed through the corner of the ventilator box
Using threaded bolts ≤5mm with a head size ≥8mm
Connecting the Spigots and Ducting
Select the spigot required to suit the ventilation requirements:
(€125mm spigot or blanking cover)
Place a worm drive clip or cable tie over the flexible duct (not
supplied).
Fix the flexible ducting to the spigot by tightening the worm drive
clip or cable tie (not provided).
Align the four locating tabs on the spigot and insert the spigot into
the unit.
Once the spigot is flush with the unit turn the spigot clockwise
until it locks firmly into position (approximately 30 degrees)
Using the one of the screws provided lock the spigot into place
and gently tighten the worm drive to create a good seal.
If an extract spigot(s) is not required they should be blanked off
with one of the blanking covers provided. The blanking cover
should be fixed into position with a locking screw provided.