IMPORTANT CUSTOMER NOTES:
This appliance can be used by children aged from 8 years and above 
and  persons  with  reduced  physical,  sensory  capabilities  or  lack  of 
experience  and  knowledge,  if  they  have  been  given  supervision  or 
instruction  concerning  the  use  of  the  appliance  in  a  safe  way  and 
understand  the  hazards  involved.  Children  shall  not  play  with  the 
appliance.
Cleaning  and  maintenance  of  the  appliance  shall  not  be  made  by 
children.

WARNING:  THE  FAN  AND  ANCILLARY  CONTROL  EQUIPMENT 
MUST

BE  ISOLATED  FROM  THE  POWER  SUPPLY  DURING 

INSTALATION OR MAINTENANCE.

Information on Maintenance and Operation:

For the Householder:

Your home has been fitted with a highly energy efficient mechanical ventilation system. The system should consist of 
an Xplus2 EC RFH central  mechanical  extract  fan,  ducting,  discharge  grille and  extract  valves  in  the  wet  rooms, 
kitchen,  bathroom  and  toilet.  The  correct  working  system  will  provide  a  healthy  indoor  atmosphere  and  will  help 
eliminate condensation and unwanted odours. 
The Xplus2 EC RFH system is designed to operate with the Xplus 2 EC RFH switch supplied.
The fan can be set to run in one of 4 modes: 

Night-time speed setting

where the fan provides background, trickle ventilation (the fan could also be set to 

run at this speed if the house is not fully occupied). 

Day-time speed setting

where the fan provides normal running conditions.

Timed boost speed setting

where the fan will run at High speed for a fixed 30 minute period. After this time 

the fan will revert to the auto / Humidity speed setting condition. This setting would be used for the extract of 
cooking smells or moisture laden air. When this is in use it is advisable to open window vents or a window to 
provide replacement air.

Auto / Humidity speed setting

where the fan runs at the day-time speed setting, adjusting to slow changes 

in natural humidity without increasing fan speed if humidity levels increase at  a rate slower  than 5% RH in 5 
minutes.  If  humidity  levels  exceed  70%  RH  or  increase  quicker  than  5% RH  in  5  minutes  the  fan  increases 
speed  to  the  humidity  speed  setting. When humidity  levels  drop  below  70%  RH  the  fan  continues  to  run  at 

[11]

This page has been left blank for the addition of any notes you may wish to make.

Summary of Contents for Xplus2 EC RFH

Page 1: ...osed of or delivered by Redring Xpelair Group Limited and a delivery charge made EXCLUSIONS This guarantee does not cover damage or defects arising from poor or incorrect installation improper use or lack of maintenance It is the responsibility of the installer to check that the installation parameters meet the requirements of the product and any relevant regulations If we are called out to a faul...

Page 2: ...s2 EC RFH system is designed to operate with the Xplus 2 EC RFH switch supplied The fan can be set to run in one of 4 modes Night time speed setting where the fan provides background trickle ventilation the fan could also be set to run at this speed if the house is not fully occupied Day time speed setting where the fan provides normal running conditions Timed boost speed setting where the fan wil...

Page 3: ...ts very little dirt However it may be advisable to have the unit inspected by your installer annually and clean if necessary Making sure that water does not get into the motor or electrical termination box CE Conformity This unit meets all relevant CE standards Characteristics The electric motor and fan are enclosed in the ventilator casing Attached to the casing is up to 6 125mm extract spigots o...

Page 4: ...ertically upwards only 9 The Xplus2 EC RFH has infinite speed control this will enable you to control the air flow of your Xplus2 EC RFH to your specific systems requirements while maximising the Xplus2 EC RFH s energy efficiency Step 10 Switch off the mains electrical supply and remove all fuses before commencing Step 11 Identify the correct speed controller for the speed you wish to adjust Step ...

Page 5: ...ce from the discharge outlet of a flued heating or cooking appliance For guidance on installation please refer to Xpelair s online installation guide Position of the discharge grille atmosphere At least 2 0 meters away from open door or window or the inlet of another ventilation device The fan must always be firmly fixed ensure the Xplus2 EC RFH unit is installed by either of the two methods liste...

Page 6: ...ouble insulated cable used with a cable cores greater than 0 75mm 2 which has been appropriately specified for this specific application by a qualified professional WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING INSTALATION OR MAINTENANCE 7 If you have any queries regarding the installation of this product please call the Technical Hotline 44 0 8709 0...

Reviews: