Installation 

 
If wall mounting the fan, you will also need: 

 

A 100mm diameter prepared hole. 

 

An appropriate external Wall Grille and Ø100mm wall sleeve duct (supplied). Cut ducting to correct length if required. 
The wall tube supplied is telescopic and can be extended to 300mm maximum. 

 
If ceiling mounting the fan, you will also need: 

 

A 100mm diameter prepared hole. 

 

A 100mm diameter prepared hole for the external grille, ideally positioned to allow condensation to run away from 
the first bend in the duct towards the external grille. 

 

Appropriate ancillaries for termination. These items are available from Xpelair: 

1.

 

3m flexible ducting Ref: 89663AA. If the duct passes through a cold space use insulated duct ref: 89847AA. 

2.

 

Soffit Grille Ref: 89742AW 

 

If window mounting the fan, you will also need:

 

 

SSWIN - Simply Silent Window Kit. Ref: 92996AA 

 
Installing the isolating switch and cables. 

 
 
 
 
 

 

 

 

1.

 

Check that the electrical rating shown inside the back-plate matches your mains supply. 

2.

 

Check there are no buried pipes or cables e.g. electricity, gas, water behind the switch location (in the wall or above 
the ceiling). If in doubt, seek professional advice. 

3.

 

Isolate the mains supply. 

4.

 

Lay in the cable from the isolating switch to the fan location via the on/off switch (if required). 

5.

 

Lay in the cable from the isolating switch to the point of connection to the mains supply. 

 
 
 
 

 

Where to locate the fan. 

 

Locate it as high as possible. 

 

At least 110mm from the edges of the mounting surface to the centre of the hole. 

 

As far away as possible from and opposite to the main source of air replacement to ensure airflow across 
the room (e.g. opposite the internal doorway). 

 

Near the source of steam or odours. 

 

 

 

Not where ambient temperatures are likely to exceed 50°C. 

 

If installed in a kitchen fans must not be mounted immediately above a cooker hob, or eye level grill. 

 

If  installing  in  a  room  containing  a  fuel  burning  device  which  has  a  non-balanced  flue,  it  is  the 
installer's  responsibility  to  ensure  that  there  is  enough  replacement  air  to  prevent  fumes  being 
drawn down the flue when the fan is operating up to maximum extract. Refer to Building Regulations 
for specific requirements. 

 

Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied 
with energy other than electric. Requirements of all authorities concerned must be observed for 
exhaust air discharge and intake flow rates. 

 

Not suitable for use in possible chemical corrosive atmospheres. 
 

 

 

 

 

Warning: Do not make any connections to the electrical supply at this stage. 

 

What the installer will need. 

 

3mm electrician’s screwdriver and No.1 or 2 Pozidrive screwdrivers. 

 

A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with wiring 
regulations 

 

If metal switch boxes are used, earthing regulations must be followed. 

 

The cross-sectional area of the supply cord used should be ranged from 1-1.5mm². 

 

DX100R / DX100S / DX100PR / DX100PS / DX100PIRR / DX100PIRS – 2 core,  

 

DX100TR / DX100TS / DX100HTR* / DX100HTR* / DX100HPTR* / DX100HPTS* – 3 core.  
* If wiring to remote switch. 

 

C4TS / C4TR / C4HTS / C4HTR. A wall or ceiling On/Off switch (with indicator light) is recommended

 

Summary of Contents for DX100R

Page 1: ... install each fan with a means for disconnection in all poles in the fixed wiring Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning Please leave this leaflet with the fan for the benefit of the user UK customers If you have any queries before or after installing this product call the Xpelair Technical Hotline 44 ...

Page 2: ...PTR DX100HPTS Operates when triggered automatically by the integral humidity sensor by using an external on off switch not supplied or by using the integral pull cord switch In automatic mode The built in timer automatically operates the fan for the pre set delay time from 30 seconds to 30 minutes once humidity drops below the pre set Relative Humidity RH value External operation When switched off...

Page 3: ...Back plate fixing positions Front Cover Removal Depress Cover Latch with tool remove Cover A C B ...

Page 4: ...Minimum 30 seconds Maximum 30 minutes Factory settings Timer 15 minutes RH 75 D E F ...

Page 5: ...Wiring and setting up G1 ...

Page 6: ...Wiring and setting up G2 ...

Page 7: ...G3 ...

Page 8: ...e centre of the hole As far away as possible from and opposite to the main source of air replacement to ensure airflow across the room e g opposite the internal doorway Near the source of steam or odours Not where ambient temperatures are likely to exceed 50 C If installed in a kitchen fans must not be mounted immediately above a cooker hob or eye level grill If installing in a room containing a f...

Page 9: ...c wall tube onto the ribbed gasket Cut the tube to the required size first if necessary 9 Feed the mains cable through the cable entry hole in the back plate to the terminals 10 Insert the fan tube into the wall duct ceiling as before 11 Fasten the back plate to the wall ceiling using appropriate fasteners supplied See figure A 12 If using screws do not over tighten Mount the back draft shutter 13...

Page 10: ...75 Relative Humidity RH but can be adjusted between 65 and 85 RH by control H The over run timer is factory set at 15 minutes but can be adjusted from 30 seconds to 30 minutes by control T Turn the controls clockwise to increase RH or time and anti clockwise to decrease Using the fan DX100R DX100S Only Operate the fan using the on off switch not supplied Repeat to switch off DX100TR DX100TS Only O...

Page 11: ...e for the adjustable time delay then goes into automatic mode Pull Cord operation Use the integral pull cord switch When the fan is switched off the fan continues to operate for the adjustable time delay then goes into automatic mode DX100PIRR DX100PIRS Only The sensor detects movement in the room and activates the fan When movement is sensed the fan will run for a pre set over run period and any ...

Page 12: ...ernational below United Kingdom Xpelair have a comprehensive range of services including Free technical advice help desk from Engineers on all aspects of ventilation Free design service quotations and site surveys Service and maintenance contracts to suit all requirements Please ask for details By telephone on Techline 44 0 844 372 7766 By fax on Techfax 44 0 844 372 7767 At the address below Head...

Reviews: