Fan Settings.
SPEED SETTING
The fans are factory set to low speed, but have two speed settings for different applications. Select either high or low speed
by connecting the jumper between the centre and high or low speed pin on the jumper (see Figure G).
DX100TR / DX100TS / DX100PIRR / DX100PIRS only.
To adjust the over-run period turn the control (T) clockwise to increase and anti-clockwise to decrease – see Figure F.
DX100HTR / DX100HTS / DX100HPTR / DX100HPTS only – see figures F and G.
The pre-set humidity operation is factory set at approximately 75% Relative Humidity (RH), but can be adjusted
between 65% and 85% RH by control H.
The over-run timer is factory set at 15 minutes but can be adjusted from 30 seconds to 30 minutes by control T.
Turn the controls clockwise to increase RH or time and anti-clockwise to decrease.
Using the fan.
DX100R / DX100S Only
Operate the fan using the on/off switch (not supplied). Repeat to switch off.
DX100TR / DX100TS Only
Operate the fan using an on/off switch (not supplied). Note – the fan may take up to 10 seconds to turn on once the
switch has been operated. When the switch is turned off, the fan continues to operate for the set time delay. To adjust
the over-run period, turn the control “T” clockwise to increase and anti-clockwise to decrease – see Figure F.
H