background image

11

    let’s face it

1.   Remove the two screws that hold the toe kick in place.  
Remove the toe kick and set aside.

2.  Remove the three screws holding the lower hinge in place.
Remove the hinge and set aside.

3.   Pull the door down away from the upper hinge to remove it
and lay it flat face down on a pad to prevent scratches. 

4.  Starting at one corner, gently pull the rubber door gasket out
of the channel.  Lay it aside, flat.  You will reinstall it shortly.
In the channel are 10 screw holes.  

5.  Attach your door handle to the frame, countersinking the screw
heads so the frame lays flat against the door.. 

6.  Align the frame to the door.  If the frame is wider than the door,
set the frame flush with the hinge side of the door, let the other side
overhang the door and clamp securely.

7  Using the (10) ST4-30 self-tapping screws supplied securely fasten 
the frame to the door.  Do not over tighten as screws may strip out.  

WARNING: Screws are sized for 3/4” panel, 
DO NOT USE these screws for thinner panels.

BEFORE BEGINNING - REST THE UNIT ON ITS BACK, WITH THE DOOR FACING UP

Summary of Contents for XOU24WDZGBL

Page 1: ...I worked really hard on this manual so please read it XOU24WDZGO PANEL READY 2 ZONE WINE COOLER WATCH THE INSTALLATION VIDEO ON OUR CHANNEL ...

Page 2: ...ou can be confident you have chosen a high quality innovative and stylish product from a company that cares about you If you require service or have questions Help is only a phone call away call 973 403 8900 Talk to one of our undercounter experts ...

Page 3: ...ice Warranty 4 7 Installation Instructions Sizes and Installation Dimensions Leveling Your XO 8 13 21 22 23 24 3 where things are please read and follow all safety instructions It s for your own good Honest Installer Checklist Find Your Model Operating Instructions Control System Overview Setting the Temperature Functions Wine and Beverage Storage Shelf Instructions 14 20 Integrated Panel Dimensio...

Page 4: ...hly inspected all surfaces for any imperfections Have you reviewed this manual with the customer and explained the unit s operation and care Has the customer received copies of the literature and keys Have you properly disposed of all packing materials properly recycle please Is the customer satisfied O O O O O O O O O O O O After installation does the door open sufficiently to fully extend the sh...

Page 5: ...5 XOU24WDZGOR XOU24WDZGOL WINE COOLERS 2 these are the models covered in this book take a minute to circle your model above and record your serial number here in case you need it later ...

Page 6: ... Failure to follow this step may cause problems Location Your XO unit should be located away from direct sunlight and heat sources stove heaters etc which may increase electrical consumption High or low ambient temperature may cause units to work improperly The floor must be strong enough to support your XO unit fully loaded Your XO unit must not be installed in areas of where water or excessive m...

Page 7: ...ic shock Exercise care when moving your XO unit to avoid damage to the electrical cord If the electrical cord of your XO unit becomes worn or damaged it must be replaced immediately by a qualified technician NEVER unplug your unit by pulling on the cord Unplug by gripping the plug firmly and pull out straight from the outlet INDOOR USE ONLY This model is intended for indoor interior applications o...

Page 8: ...DERCOUNTER UNITS ARRIVE PRE WIRED WITH LOW PROFILE PLUGS FOR EASY INSTALLATION 4 7 34 1 4 MIN 24 90 Door Swing WALL Clearance Gap IF THE DOOR CAN T OPEN FULLY YOU CAN T PULL THE SHELVES OUT WHEN INSTALLING WITH THE HINGE SIDE NEXT TO A WALL LEAVE ADEQUITE SPACE FOR CABINET HANDLES DOOR MUST BE ABLE TO OPEN A MINIMUM OF 90 o THE DOOR STOP IS SET AT 110 BUT CAN BE REST TO 90 OR 140 IF NEEDED o o o ...

Page 9: ... 8 W H height width MODELS WITH OVERLAY DOORS depth 23 3 4 D CUSTOM OVERLAY PANELS MAY ADD UP TO 3 4 IN OVERALL DEPTH YOUR CHOICE OF CABINET HANDLES WILL ALSO ADD DEPTH 23 7 8 WIDE 90o 110o 140o DOOR MUST BE ABLE TO OPEN 90 MINIMUM TO ALLOW SHELVES TO EXTEND WITH THE DOOR OPEN AT 90 THE UNIT HAS A DEPTH OF 46 1 2 o ...

Page 10: ... dimensions xou24wdzgo Drill a hole at least 5 16 in diameter and 1 deep into the top and bottom of the frame in the location shown TO ACCOMMODATE THE HINGE PINS ON THE HINGE SIDE OF THE PANEL 2 7 8 73mm min 5 127mm max IF FRAME WIDTH EXCEEDS 23 3 4 WHEN MOUNTING TO THE DOOR ALIGN THE FRAME EVEN WITH THE HINGE SIDE LETTING THE EXCESS OVERHANG THE HANDLE SIDE TO AVOID INTERFERENCE WITH THE ZERO CLE...

Page 11: ...reinstall it shortly In the channel are 10 screw holes 5 Attach your door handle to the frame countersinking the screw heads so the frame lays flat against the door 6 Align the frame to the door If the frame is wider than the door set the frame flush with the hinge side of the door let the other side overhang the door and clamp securely 7 Using the 10 ST4 30 self tapping screws supplied securely fas...

Page 12: ...g the two screws removed in Step 1 ADJUSTMENT SCREWS TOP BOTTOM If the door requires adjustment the top and bottom hinge each have adjustment screws Loosen the screws then with the door open raise the handle side to level and re tighten the screws The door hinge stop is set at 110 change it to either 90 or 140 Simply change the position of the stop screw in the lower hinge plate as shown o o o OPT...

Page 13: ...rners until all four legs are seated firmly on the floor and the interior floor of the unit is level both front to back and side to side Failure to follow this important step may cause problems with proper door operation excessive condensation vibration and noise 13 it s like zen but cooler get your level out ...

Page 14: ...re usually normal Sounds can also be amplified by hard surfaces like flooring or tiles Here is a description of the types of sounds you might hear and what might be causing them may run longer than your old unit You might also hear a pulsating or high pitched sound as the compressor and fans adjust to improve performance During defrosting cycles you may hear some water running into the drip pan The ...

Page 15: ... out of direct sunlight to limit both UV and heat exposure VIBRATION Vibration is another element that can harm wine Your XO Wine Cooler has design features to aid in limiting the transmission of vibration to the bottles however it is advisable to install your wine cooler in an area away from loud speakers power equipment heavy floor traffic and similar noise generators HUMIDITY High or low humidi...

Page 16: ...wing the compartment temperature To view the real time temperature press and hold the button for 5 seconds The interior temperature will flash in the LED Display for 5 seconds If you wish to change the display from Fahrenheit to Celsius or vice versa press and hold both and simultaneously for 5 seconds led lights L1 When you turn on your wine cellar the internal light will switch on when the door ...

Page 17: ...pliance will operate however it will not respond to your actions To initiate Sabbath Mode Press and hold both for 5 seconds The display will show either Sb or Sb On depending on the model you have to indicate Sabbath Mode is engaged To turn Sabbath Mode off and return to Standard Mode Press and hold both f Press for 5 seconds DEMO mode is turned on Press for 5 seconds again DEMO mode is turned off...

Page 18: ... Functions L1 L2 L3 TEMPERATURE DISPLAYS UPPER LOWER Indicator Light Cooling Mode ON Press to raise temperature Press to lower temperature Changes interior light color Toggles between different operating modes 18 UPPER LOWER Upper compartment The temperature setting can be adjusted from 41 50 F Lower compartment The temperature setting can be adjusted from 50 64 F dual zone control 2 zone wine coo...

Page 19: ...of 7 5 Racks of 7 35 6 l 5 u 35 6 l 5 u 24 2 MODEL WIDTH ZONES BORDEAUX BURGUNDY 46 TOTAL 46 TOTAL Shelf capacities Store wine in sealed bottles only Avoid overloading Storing little or no product can cause excessive condensation 19 how many wine bottles can this hold XOU24WDZGO 24 Wide Wine Cellar Racks accommodate up to 7 Bottles Each ...

Page 20: ... rack STEP 2 Remove and re position the rack glides STEP 3 Reverse the steps LIFT THE FRONT PULL OUT STRAIGHT Install the right and left RACK GLIDES in their new position by pushing the pins into the slots and click the front of the glide down to secure Replace the rack ALL RACKS MUST BE PUSHED ALL THE WAY IN BEFORE CLOSING THE DOOR DOOR MUST BE FULLY OPENED BEFORE PULLING RACKS OUT 20 juggling sp...

Page 21: ... the wine cooler power failure Most power failures are corrected within a few hours and should not affect the temperature of your appliance if you minimize the number of times the door is opened If the power is off for a longer period of time you need to take the proper steps to protect your contents vacation Short vacations Leave the XO unit operating during vacations of less than three 3 weeks L...

Page 22: ...l straight out to remove Align the tabs and insert the new filter Rotate filter 1 4 turn to lock in place Your Air Refresh Charcoal Filter I P N XOUAIRFILTER s Located Here 22 a breathe of fresh air for best results change every 3 to 6 months ...

Page 23: ... you have not recently added a large quantity of warm bottles it may be a mechanical issue Unplug the unit and call for service The alarm is beeping and LO is displayed on the control panel This may be a sensor malfunction Unplug the unit and call for service Why does condensation form on the inside or outside of my XO unit It may be that the door is either opened repeatedly or not closed complete...

Page 24: ...me obligations other than those expressly covered by this warranty Open box factory seconds scratch and dent floor models and commercial applications are excluded from these warranties Consumer shall be responsible for labor and transportation costs where noted above NO CONSEQUENTIAL DAMAGES XO is not responsible for economic loss profit loss or special indirect or consequential damages including ...

Reviews: