- 14 -
1. Route the power cord to the junction box.
2. Using listed conduit fittings and connectors, connect the power supply to the box and
each line to the appropriate wire following this color convention:
BLACK = HOT LEG
WHITE = NEUTRAL
GREEN/YELLOW = GROUND
Polarity must be observed.
Unit must be properly grounded.
Use a double throw disconnect switch.
3. Replace the box cover
Replace the Anti-grease flters.
All wiring must be in compliance with national electrical code, ANSI/NFPA 70-1999
and all local codes and regulations.
electrical connection
A
Lift the electrical plant box.
B
Remove the 3 fixed screws.
C
Position the electrical box so it is in the line with the holes of the previously removed
screws and tighten.
A
B
C
D
D