background image

 

                                                                    6/23               

©

PHANTOS

®

 

    Distributed in Australia by PHANTOS    www.phantos.com.au   

 

ShortCut: 

 

 

Off 

Shortcust off for colors and GOBOS 

On 

Shortcust open for colors and GOBOS 

 

 

ADV. 

(ADVANCED FUNCTION) 

RST. 

Re-setting and back 

SAVE 

Save and return 

ESC   

Save and return 

ADVANCED 

FUNCTION 

Redress 

 

Pan rotation 

0-255 

Motor initial calibration. Not for 

manual control. Only to be used by 

service technicians. 

Tilt rotation 

focus 

zoom 

Cyan+Blue 

Magenta 

Yellow 

Color 

temperature 

Color wheel 

Dimming 

aperture 

Fixed GOBO 

Prism Rota 

GOBO Rota 

Prism 

Prism Rota 

FROST 

ESC 

 

 

ChanlDef 

 

 

 

 

No function 

FactSett 

 

 

   

For factory only 

UseManage 

Limit 

LimitTime 

No function 

limitCont 

No function 

DefConfig 

YES 

Return to default 

NO 

Exit Menu 

Summary of Contents for EXP370 LED HYBRID

Page 1: ...velopment specifications are subject to change without notice Whilst every care is taken in the preparation of this manual we reserve the right to change specifications in the course of product improv...

Page 2: ...ages caused by the non observance of this manual or any unauthorized modification to the device 1 1 What is Included a 1X XMLite EXP370 Moving Head Hybrid b 1X user manual c 1X safety cable d 2X Mount...

Page 3: ...stated on decal or rear panel of the fixture To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure power cord is never crimped or damaged Do not attempt to operate this...

Page 4: ...more fixtures using a DMX 512 controller or to run synchronized shows on two or more fixtures in master slave operating mode you need DMX cables to link the units from DMX IN to DMX OUT Only use stan...

Page 5: ...ing the DMX control signals The DMX terminator is simply an XLR connector with a 120 ohm resistor connected across pins 2 and 3 which is then plugged into the output socket on the last projector in th...

Page 6: ...ctive Auto not active Channel Mode 24CH 24CH model 16CH 16CH model Pan Reverse Off Pan Scan Normal On Pan Scan Reverse Tilt Reverse Off Tilt Scan Normal On Tilt Scan Reverse Opto Check Off Pan Tilt op...

Page 7: ...ADVANCED FUNCTION Redress Pan rotation 0 255 Motor initial calibration Not for manual control Only to be used by service technicians Tilt rotation focus zoom Cyan Blue Magenta Yellow Color temperatur...

Page 8: ...xit Menu MANUAL LAMP REST ALL MOTER All step motor do not adjust it XY MOTER Pan Tilt step motor adjust do not adjust it PART MOTER Other step motor except Pan Tilt YES The chosen step motor reset ESC...

Page 9: ...ALL MOTER Right Erro Motor reset state XY MOTER PART MOTER ESC Back OTHER INFO Run Time 0 9999 Machine running hours Run Count 0 9999 Open times memo Residue T Most No limit time Residue C Most No li...

Page 10: ...n Menu back after 1 min 2Min Menu back after 2 mins 3Min Menu back after 3 mins Light Flash Off Back ground light flash function off On Back ground light flash function on Touch Cali Off Touch screen...

Page 11: ...ne 5 3 Pan Tilt speed 0 255 Pan Tilt speed 6 4 Function setting 0 139 Empty 140 149 PAN TILT reset 150 159 Empty 160 169 Small motors reset 170 199 Empty 200 209 Whole unit reset 210 255 Empty 7 5 Col...

Page 12: ...GOBO 1 10 15 GOBO 2 16 21 GOBO 3 22 27 GOBO 4 28 33 GOBO 5 34 39 GOBO 6 40 45 GOBO 7 46 51 GOBO 8 52 57 GOBO 9 58 87 The effect GOBO from slow to fast shake 88 95 GOBO 1 Shake 96 103 GOBO 2 Shake 104...

Page 13: ...GOBO 1 8 10 GOBO 2 11 13 GOBO 3 14 16 GOBO 4 17 19 GOBO 5 20 22 GOBO 6 23 25 GOBO 7 26 28 GOBO 8 29 31 GOBO9 GOBO Location GOBO rotation indexing mode 32 34 GOBO 1 35 37 GOBO 2 38 40 GOBO 3 41 43 GOBO...

Page 14: ...6 Shake 178 185 GOBO 7 Shake 186 193 GOBO 8 Shake 194 199 GOBO 9 Shake 200 201 Maximum Aperture 202 221 Run from fast to slow in clockwise 222 223 Stop 224 243 Run from slow to fast in anti clockwise...

Page 15: ...6 176 183 Macro 7 184 191 Macro 8 192 199 Macro 9 200 207 Macro 10 208 215 Macro11 216 223 Macro 12 224 231 Macro 13 232 239 Macro 14 240 247 Macro 15 248 255 Macro16 15 11 Prism Rota Rota Index 0 25...

Page 16: ...pty 22 15 Strobe 0 31 Strobe Close 32 63 Strobe Open 64 95 Strobe from slow to fast 96 127 Strobe Open 128 143 fast open slow close step out Fast to slow 144 159 slow open fase close step in slow to f...

Page 17: ...cap back in place and reconnect power 4 2 Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output 1 Use n...

Page 18: ...ality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective fixture disturbing the link Bad data link conne...

Page 19: ...missing or blown Disconnect fixture and replace lamp Lamp cuts out intermittently Fixture is too hot Allow fixture to cool Clean fan if applicable Make sure air vents at control panel and front lens a...

Page 20: ...ntos com au 5 TECHNICAL SPECIFICATIONS WEIGHT DIMENSIONS Length 61 9cm Depth 26 6cm Height 36 8cm Weight 19 1kg POWER AC Power AC110 240V 50 60Hz Power Consumption 300W MAX Fuse LIGHT SOURCE 170W LED...

Page 21: ...description of the symptoms All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Phantos Lighting will pay return...

Page 22: ...pon its products without any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory suppli...

Page 23: ...in Australia by PHANTOS www phantos com au Phantos Lighting 45 7 9 Percy St Auburn NSW 2144 Australia 02 8034 8680 www phantos com au info phantos com au Stay Connected facebook com phantoslighting tw...

Reviews: