2. SET UP
2.1 Mounting
With adjustable mounting double brackets, this unit may be wall mounted, free
standing, or clamp mounted.
IMPORTANT!!! Safety cables must always be used. The safety cable must
be capable of holding 10 times the weight of the fixture.
2.2 Fixture Linking
To run your light shows of one or more fixtures using a DMX-512 controller or to
run synchronized shows on two or more fixtures in master/slave operating mode,
you need DMX cables to link the units from DMX IN to DMX OUT.
Only use standard 110-120 Ohm shielded cable. These are 2 core-screened
cables, with each core having at least a 0.5mm diameter. Do not use the
ground lug on the XLR connector. Do not connect the cable
’
s shield
conductor to the ground lug or allow the shield conductor to come in contact
with the XLR’s outer casing. Grounding the shield could cause a short circuit
and erratic behavior.