XMG OASIS User Manual Download Page 10

10

 

 

9. Operate your XMG OASIS 

1.

 

Make sure that laptop and XMG OASIS are connected to external 

power and that the water tubes are firmly attached. 

2.

 

Power on your laptop and make sure that Bluetooth is turned on as 

well. 

3.

 

Press the power button on the XMG OASIS main unit. The LED 

indicator of the power button will start pulsating in blue color. 

4.

 

Open the Control Center on your laptop and find the XMG OASIS 

control module. At first run, the application will pop up with a short 

tutorial. The exit button is on the last page of the tutorial. 

5.

 

Click the “Connect” button. XMG OASIS will now pair with your laptop 

via Bluetooth. At this moment, the fan and pump will start operating. 

6.

 

Check all ports for leakage after five minutes. If you find any drops of 

fluids on the chassis or on the surface below, turn everything off, 

disconnect power and check the connections. 

7.

 

During longer use, the water level may slowly drop due to evapo-

ration. Small drops of liquid are also lost when disconnecting the 

quick release connector from the laptop. Please check the water 

level behind the front lens of the main unit on a regular basis. 

Optimal water level is about 1

cm below the “Maximum” line. 

  Water expands as it gets hotter. If you fill over the Optimum line, increased 

water pressure during prolonged operation may cause liquid to push against 

the refill port cover, causing small leaks through the top of the main unit. 

   XMG OASIS will automatically go to standby and the pump and fan will stop 

if host laptop enters standby, hibernate or shutdown. 

   XMG OASIS will automatically reconnect to host laptop if the Control Center 

is installed on the laptop and the devices are within Bluetooth range. 

10. Stop operation of XMG OASIS 

1.

 

In the XMG OASIS module of the Control Center, click on the “Discon-

nect” button. Wait a few seconds until the fan and pump inside the 

main unit have come to a full stop. 

2.

 

Power down XMG OASIS by pressing the power button on the top of 

the main unit. When the device is powered down, all LEDs will be off. 

Summary of Contents for OASIS

Page 1: ...XMG OASIS The first portable laptop watercooling User Manual...

Page 2: ...al laptop air cooling systems with similar power levels The system comes with accessories that are required for operation and maintenance Before transporting XMG OASIS or its host laptop all liquid mu...

Page 3: ...tor power button LED 3 colors Communication Bluetooth Low Energy LE Power supply DC in powered by 19 5 V or 20 V laptop power adapter DC out forwards power to host laptop through DC cable Plug dimensi...

Page 4: ...uct overview Front side view Left side view Back side view Right side view The power cord can be wrapped and stored around the base 1 drainpipe sockets 2 RGB LED 3 DC port 4 vents 5 power connector 1...

Page 5: ...view 6 refill port cover 7 power LED indicator 8 power button Power LED indicator color codes blue blinking Bluetooth searching blue steady Bluetooth connected purple blinking Liquid Input Mode orange...

Page 6: ...e in the original box of XMG OASIS 6 Gently attach the black connectors of the water tubes to the main unit by carefully tightening the screws Avoid twisting the tubes during this process Stop tighten...

Page 7: ...nector is reversible meaning the orientation which tube connects to which port does not matter Connect it in such a way that the tubes do not get twisted Keep them straight and parallel do not bend th...

Page 8: ...move from coolant liquid to distilled water it is recommended to fully empty all liquid from the coolant loop first You should NEVER fill in tap water mineral water or any other food liquid not even...

Page 9: ...ndicating that it has entered Liquid Input Mode During this mode the pump will work to push liquid from the reservoir into the cooling loop 5 The water level behind the front lens will drop Add additi...

Page 10: ...drop due to evapo ration Small drops of liquid are also lost when disconnecting the quick release connector from the laptop Please check the water level behind the front lens of the main unit on a re...

Page 11: ...ve all fluids keep all surfaces clean and dry 6 Now close the rubber seal of the laptop This operation may cause additional liquid to be squeezed out around the edges and the ventilation hole of the r...

Page 12: ...he drainage adapter towards a small container or tissue paper Slowly swerve left and right in order to release all liquid 4 To remove the last few drops of liquid put the laptop back into the horizont...

Page 13: ...his bridge is not very stable If you accidentally pull on the tubes or the laptop possibly by accident but also by children or pets the two transparent little tubes of the drainage adapter will be pul...

Page 14: ...ut Risk of freezing temperatures Environmental temperatures below 5 C 41 F might cause damage to pipes and connectors by freezing the liquid that is still trapped inside High risk of irreparable perma...

Page 15: ...from the tubes 5 Carefully raise the main unit with one hand while still aiming the tubes into your container Let gravity assist the process 6 When the liquid stops flowing gently tilt the main unit...

Page 16: ...such a mode of transportation is risky and will lead to liquid damage in case of accidents or negligence Leakage may cause permanent damage to XMG OASIS and to surrounding electronics and sensitive ob...

Page 17: ...inside the tubes or around the pump With the tubes connected to your laptop enter Liquid Input Mode a few times This might help to disperse air bubbles inside the system Alternatively follow the inst...

Page 18: ...uid in the process When full a tilt angle of 29 degree is enough to cause the device to tip over to the side This may cause considerable amounts of liquid to escape from the refill port on the top of...

Page 19: ...drain all liquid from the device disconnect the tubes from the device reconnect the hexagon water stoppers to the front of the device The device must be tilted at different angles to be fully drained...

Page 20: ...ce manual A service manual with disassembly steps is located in the download portal on our website The service manual is for reference only and does not express an encouragement to disassemble the dev...

Page 21: ...you find no more fluids with fresh dry tissue tips 9 Disconnect the water tubes from the laptop without moving the laptop Dry off the water ports See page 11 for details 10 Leave the laptop in this po...

Page 22: ...ring up the device Do not power on the device if there is no liquid inside the device If the tubes are connected to the laptop but water is not flowing i e if OASIS is not operating the connector may...

Page 23: ...ee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Page 24: ...24 Scan this code to find your answer in our FAQ Contact Schenker Technologies GmbH Walter K hn Str 2C 04356 Leipzig GERMANY E Mail support xmg gg Do you have any more questions...

Reviews: