background image

USER MANUAL - OPTIMA UPS 6K/ 10K (ENGLISH) 

______________________________________________________________________________________________________________________ 

 

20150610 Tower-Rack 6K-10K ISOTX

 

 - 41 

  14.- LIMITED WARRANTY   

 

 

 

 

 

               

 

Support: 

If a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved 

please contact authorized service center or authorized dealer. 

 
Batteries:

 Rechargeable batteries can be charged and discharged hundreds of times. However they will eventually wear out. 

This is not a defect or failure so that batteries wear out is not covered by this warranty. 
Battery lifetime will depend of operative conditions like working temperature, type and frequency of discharging cycles. Higher 

the temperature shorter will be the lifetime. Frequent and deep discharging cycles also will short lifetime. For critical 
applications batteries should be revised and replaced periodically. Long storage (longer than 6 months) without required 
recharging will wear out batteries. This situation is not covered by this limited warranty since this is not considered as a 
defect. Check recharging instructions on user manual. 

 
Conditions Limited Warranty “X-UPS” 

1.- Subject to the conditions of this limited warranty, this product is warranted to be free from defects in materials and 

workmanship at the time of XMART supplies the product. 
Standard warranty times could vary depending on country/region or can be extended by purchasing warranty options. Please 
check warranty plans and extensions with your local distributor or revise in our web www.xmart-ups.com. 
2.- If during the warranty period, this product fails to operate under normal use and service, due to defects in materials or 
workmanship, authorized distributor or service center will, at their option, either repair or replace the product in accordance 

with terms and conditions stipulated herein. Transportation expenses are not covered by this limited warranty. 
3.- Warranty is valid only if the original invoice issued by XMART, specifying date of purchase, serial number and name of the 
dealer, is presented with the product to be revised. XMART and authorized partners reserve the right to refuse warranty service 
if any of this information has been removed, changed or missing in original invoice document. 
4.- If product is repaired or replaced, repaired or replaced product will be warranted for the remaining time of the original 
warranty or for 90 days on repaired part from date of repair, whichever is longer. 

5.- XMART or their distribution/service partners reserve the right to charge handling fee if returned product is free of failure or 
it is out of warranty because any of the reasons described in this warranty.  
6.- If product is out of warranty a reparation proposal will be sent to the user for his approval. If proposal is not accepted, 
service center will keep product available for the user during 60 continuous days. After this period product would be disposed 
and user will not be able to rise any claim.  

7.- Rechargeable batteries, like included in this product, will definitively wear out even under normal operation. This is not a 
defect or failure so it is not covered by this warranty.  
8.- This warranty does not cover batteries wear out caused by improper or long storage (over  6 months without required 
recharging indicated in product manual). Even performing recharging procedure this product cannot be storage longer than 18 
months. Problems on batteries caused by this kind of long storage are not covered by this warranty. 
9.- This warranty does not cover product failures caused by installations, modifications or repair performed by non authorized 
person. If product is open by not authorized technician warranty will be considered void. This warranty does not cover failure 
caused by inadequate installation or maintenance, misuse, accidents, fire or floods. 
10.- This product can include protection devices like input fuse or input breaker. Activation of this kind of devices is not a 
failure it is caused by an improper product installation. Input fuse or breaker reset or replacement is not covered by this 
warranty.  
11.- This warranty does not cover damages produced during transportation from user to technical service caused by improper 
packing of the product by user. 
12.- Warranty terms and conditions cannot be modified or extended by third parties without written approval of XMART. 

 

Limited Warranty “X-UPS” 

- XMART does not warrant that the operation of this product will be uninterrupted or error-free during its lifetime. If product 

fails to work, the maximum liability of XMART under this limited warranty is expressly limited to the lesser of the price you 
have paid for the product or the cost of repairing or replacement of any hardware components that malfunction in conditions 
of normal use. 
- In no event will XMART be liable for any damages caused by the product or the failure of the product to perform, including 
any lost profits or savings or special, incidental, or consequential damages. XMART is not liable for any claim made by a third 

party to XMART or to final user.  
- XMART is not responsible for damage that occurs as a result of your failure to follow the instructions intended for this 
hardware product. 
- XMART is not responsible for damage that occurs as a result of your failure to follow the instructions intended for this 
hardware product. 
 

 

Summary of Contents for Optima 6K

Page 1: ...ENGLISH VER 150610 TOWER AND RACK UPS USER MANUAL DOUBLE CONVERSION UPS...

Page 2: ...roperty of XMART This manual Information cannot be copied or distributed totally or partially without written approval of XMART XMART can introduce modifications in their products or manuals without f...

Page 3: ...LINES CONFIGURATION AC TERMINAL BLOCKS EXTERNAL BATTERY CONNECTION 5 UPS INSTALLATION PARALLEL UPS TERMINAL BLOCK GENERAL COMMENTS UPS AC LINES CONNECTION PARALLEL CONTROL CABLES CONNECTION 6 START U...

Page 4: ...There are dangerous voltages in DC Direct Current Capacitors Please Check Capacitor location in Figure 8 4 1 Wait at least 10 minutes after turning off UPS before opening it to access inside DANGER P...

Page 5: ...quency Magnetic Field IEC EN 61000 4 8 Level 4 EMS Low Freq Signals IEC EN 61000 2 2 EMS ESD IEC EN 61000 4 2 Level 4 EMS RS IEC EN 61000 4 3 Level 3 EMS EFT IEC EN 61000 4 4 Level 4 EMS SURGE IEC EN...

Page 6: ...S 6KEX 10KEX ISOTX for RACK UPS is an optional external module can be connected at any moment to the UPS Model Internal Batteries Ext Batt Connector Isolation Transformer 6KEX 10KEX Y Y No 6KEX 10KEX...

Page 7: ...ypass Switch Interruptor Bypass 3 EPO Emergency Stop Parada Emergencia 10 AC Input Breaker Breaker Entrada AC 4 Share Current for parallel UPS para UPS paralelas 11 FAN ISOTX Ventilaci n para ISOTX 5...

Page 8: ...tor Bypass 3 EPO Emergency Stop Parada Emergencia 10 AC Input Breaker Breaker Entrada AC 4 Share Current for parallel UPS para UPS paralelas 11 FAN ISOTX Ventilaci n para ISOTX 5 Parallel Port for par...

Page 9: ...RS 232 2 USB 3 EPO Emergency Power Off 4 Share Current Port for parallel function 5 Parallel Port for parallel function 6 SNMP Intelligent Slot 7 Cooling Fans 8 External Bypass Switch port MBS port 1...

Page 10: ...technical requirements described by this manual In that case end user electrical contractor must be sure to comply with all related local electrical regulations and directives WARNING Power lines must...

Page 11: ...ver rise over 35 C Batteries life shortens over 25 C Installation site must be dry fresh free of dust fibers and any other objects conductors or not suspended in the air that could get into the UPS th...

Page 12: ...ded with rack cabinets If not UPS distributor can provide original telescopic guides as optional accessory Small black handles included with the UPS are only for locking purposes UPS cannot be support...

Page 13: ...tilation and it will allow service UPS when required Do not put any object on the UPS do not apply any force over UPS Do not cover UPS ventilation ELECTRICAL REQUIREMENTS MANDATORY All Power lines mus...

Page 14: ...ring min size 8 AWG 10 mm2 ISOTX UNIQUE OUTPUT 1 x 120Vac 100 Watts SEPARE OUTPUTS 2 x 120Vac 50 Watts C U 6KVA con ISOTX Output 110 220V Unique Output Capacity 6000VA 4800W Output Voltage 120Vac AC B...

Page 15: ...Tower Rack 6K 10K ISOTX 15 LEAK CURRENT PROTECTION In many countries now a day it is legally required to install protections against current leakage to protect human beings in cases of leaks o dischar...

Page 16: ...plug UPS to AC Line as usually ratings of this kind of outlets are not enough to power 6KVA UPS UPS Input wire must be connected by breaker protected line to electric panel board UPS Input and Output...

Page 17: ...____________________________________ 20150610 Tower Rack 6K 10K ISOTX 17 ISOTX UPS MODEL CAN BE CONFIGURED IN 3 DIFFERENT MANNERS 1 TWO separate 110Vac isolated outputs Each 50 of total UPS capacity 2...

Page 18: ...__________________________________________________ 20150610 Tower Rack 6K 10K ISOTX 18 RACK TYPE UPS 6 10K Optional ISOTX Module for RACK UPS 6 10K ISOTX module is optional accessory rack module UPS A...

Page 19: ...ION PROCEDURE UPS Tower type 1 Check all DC breakers are in OFF position 2 Remove all DC connector covers in UPS and EXBATT cabinets 3 Using appropriate cable supplied with the EXBATT connect UPS with...

Page 20: ...s kind of outlets are not enough to power 6KVA UPS UPS Input wire must be connected directly to electric panel board UPS INPUT AND OUTPUT CONNECTIONS Connect input and output ground wires to proper pl...

Page 21: ...PS 6K 10K ENGLISH ______________________________________________________________________________________________________________________ 20150610 Tower Rack 6K 10K ISOTX 21 MODEL 6K 10KEX PARALLEL UPS...

Page 22: ...6K 10K ENGLISH ______________________________________________________________________________________________________________________ 20150610 Tower Rack 6K 10K ISOTX 22 MODEL 6K 10K ISOTX PARALLEL U...

Page 23: ...IMA UPS 6K 10K ENGLISH ______________________________________________________________________________________________________________________ 20150610 Tower Rack 6K 10K ISOTX 23 PARALLEL UPS CONTROL W...

Page 24: ...RE 1 Make sure all equipments connected to UPS are off 2 Power AC input at electrical panel board by setting input AC Lines Circuit Breaker to ON 3 Put Battery Bank breaker to ON Only for Ex Models If...

Page 25: ...by activation of Emergency Switch which must be Normally Closed type in order to guarantee that UPS will shut down when circuit opens 5 Check Maintenance Bypass Switch MBS located in UPS rear panel is...

Page 26: ...f LCD 12 All UPS will go to NORMAL Online mode at same time 13 Before setting to ON all external output breakers please revise AC voltage output on each UPS Please measure AC output voltage using a di...

Page 27: ...ks as ESCAPE key when LCD is in configuration menu mode TEST UP BATTERY TEST By selecting TEST key UPS enters into battery test mode during 10s UP It Works as UP key when LCD is in configuration menu...

Page 28: ...alarms error icons 2 ELAPSED TIMER When UPS switches to battery mode elapsed time during battery mode is displayed in Hours Minutes Seconds 3 ERROR ALARM CODE In case of alarm or error 2 digits code...

Page 29: ...with AC Line directly If under this mode UPS detects AC input is out of acceptable range it enters into Normal Online mode If an AC failure occurs under ECO mode the UPS s inverter starts working drai...

Page 30: ...d by inverter FREQUENCY CONVERTER FUNCTION CF CF function enable to generate output frequency as selected IMPORTANT NOTE When CF is activated bypass mode is automatically disable and maximum power out...

Page 31: ...have their own external protections to allow total electrical isolation 6 There must be enough physical room to allow comfortable access to all UPS of the system Note if any of the above requirements...

Page 32: ...isable 6 Voltage Range for ECO mode 7 Frequency Range ECO mode 8 BYPASS mode 9 Battery Backup Security Time 10 Programmable Output note 1 11 Programmable Output Settings note 1 11 NO Battery startup f...

Page 33: ...Automatic Under this mode output frequency is selected according to input frequency 50Hz if input is 46Hz y 54Hz and 60Hz if input is 56Hz y 64Hz ATO mode is factory default value Parameter 3 Frequenc...

Page 34: ...before trying to enable it If ECO mode is disable next programs 06 and 07 don t need to be configured 06 ECO MODE Input Voltage Range LCD Parameter 2 Sets acceptable low voltage limit Parameter 3 Set...

Page 35: ...tputs OFF ATO This option allows programmable outputs to turn off when timer value is reached or very low voltage level whatever occurs first 11 PROGRAMMABLE OUTPUTS CONFIGURATION LCD Parameter 2 001...

Page 36: ...IS FACTORY SET VALUE 14 BATTERY CHARGER ADJUSTMENT LCD Parameter 2 Select Add or Sub for adjusting battery charger voltage Add or Reduce Parameter 3 available adjustment value is from 0V a 9 9V Factor...

Page 37: ...it 24 Inverter Relay Short Circuit 28 Battery connection problem BATT FAULT 35 Parallel Communication problem 36 UPS Output Short Circuit 41 HIGH Temperature 42 CPU communication problem 43 UPS Output...

Page 38: ...re Batteries and charger must be inspected by qualified personnel Code 28 Active Continuous beep Very low voltage at batteries or charger failure Batteries and charger must be inspected by qualified p...

Page 39: ...te Ext Charging Amps Corriente de Carga Charging Voltage Voltaje Cargador 2 0 A Max 273 0 VDC 96 92 EX ISO 90 86 EX ISO 88 84 EX ISO Depending on external battery configuration depende de cantidad de...

Page 40: ...ador de aislamiento con salida dual 2 x 110Vac Rack 6K 10K UPS Battery 3rd optional cab for ISOTX Rack 6K 10K UPS Bater as 3er por opci n Transf ISO opcional Specifications may change without further...

Page 41: ...ndling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is out of warranty a reparation proposal will be sent to t...

Reviews: