Each of these Joint Profiles has the following tracking position selections:
•
TL – Top Left
•
TLC – Top Left Centre
•
TLI - Top Left Inside
•
TC – Top Centre
•
TRI – Top Right Inside
•
TRC – Top Right Centre
•
TR – Top Right
The
System State Indicator
has the following states:
•
INITIALISE
: Shown during initialisation of application
•
READY
: Operate Signal is Off – waiting to start tracking
•
SEARCH
: Operate Signal is ON – Laser is On and searching for joint bead.
Once the position is within the threshold range then the status will change to
TRACKING
•
TRACKING
: Sensor is following weld joint and position correction moves are
being sent.
•
ERROR
:
A serious error has occurred. The system will not track in this state.
•
BL – Bottom Left
•
BLC – Bottom Left Centre
•
BLI - Bottom Left Inside
•
BC – Bottom Centre
•
BRI – Bottom Right Inside
•
BRC – Bottom Right Centre