background image

7

 

 

3)

 

The lift must be installed in level from front-to-back and side-to-side. 

4)

 

Make sure that the lift is level in all directions and weight should be shared 
equally by all four threaded mounting rods. 

5)

 

Bottom of the lift must be unobstructed after installation.  

 

3.

 

Installing on the Ceiling 

CAUTION:  

It is installer’s responsibility to make sure that the ceiling structure can 
support at least FOUR times the total weight of the lift and the projector. 
Reinforce the structure as required before installing the lift. 

 

1)

 

Please check that the ceiling has enough space to mount the lift. 

2)

 

 

No mounting material is provided.

 Please use suitable anchors and 

fasteners base on the ceiling type. 

3)

 

Mount two adjustable ceiling mounting bars to the ceiling. In case the ceiling 
has limited space, the installer has the option to mount the lift directly to the 
ceiling and threaded rod without using adjustable ceiling mounting bars.  

4)

 

Please refer the table below for mounting holes distances. 

 

 

A (mm) 

B (mm) 

C (mm) 

D (mm0 

XCU 190 

570 

680 

570 

495 

XCU 180 

530 

640 

530 

500 

 

Summary of Contents for XCU 190

Page 1: ...0 X Cube Lift Model XCU 190 XCU 180 Installation Instructions...

Page 2: ...ions 4 Dimensions 5 Installation Instructions 1 Preliminary Checking 6 2 Guidelines for Installations 6 3 Installation on Ceiling 7 4 Connecting to Power Supply 9 5 Installation of Projector 9 6 Cable...

Page 3: ...stalled at the ceiling before operating 4 Please do not allow children or mental disability person to operate the equipment 5 Do not install the lift on adjacent ceiling or light fixture 6 Entire bott...

Page 4: ...om heated surface 4 Please turn off power supply or unplug before cleaning or servicing THE X CUBE LIFT Overview The lift is powered by a tubular motor which is operated on Single phase 230 240 V AC w...

Page 5: ...nsumption 100 W 100 W Voltage 230 240V AC 50 Hz 230 240V AC 50 Hz Rated Current 0 5 A 0 5 A Max Travel Distance 1500 mm 1500 mm Projector Cage W x D x H 550 x 550 x 250 mm 450 x 510 x 200 mm Exploded...

Page 6: ...5 Dimensions A mm B mm C mm D mm E mm F mm XCU 190 700 640 525 680 570 12 XCU 180 660 600 330 640 530 12...

Page 7: ...lift to install at ceiling is 950mmWx850mmDx650mmH for XCU 190 and 900mmWx800mmDx450mmH for XCU 180 The installer must be accessible to every sides of the lift in order to install it 5 Check the dime...

Page 8: ...the lift and the projector Reinforce the structure as required before installing the lift 1 Please check that the ceiling has enough space to mount the lift 2 No mounting material is provided Please...

Page 9: ...tend more than 2 600mm If the rods need to extend more than 2 please use the cross bracing to enhance the stability 8 Use the threaded locking compound angle nuts to prevent swinging 9 Adjust the thre...

Page 10: ...he recommended cable size is 1 5mm2 16AWG The power supply has to connect to the building wires and a disconnection means must be provided in accordance with the wiring rules 5 Installing Projector 1...

Page 11: ...er 1 The ceiling cover is fixed at the underside of the lift which normally greater in size and serve as platform to receive all types of ceiling materials The lift must be lowered down in order to fi...

Page 12: ...if continuous operated for more than 4 minutes If such things happen please wait for the motor to cool down and restart it again The hand held transmitter remote control is paired with the lift in fa...

Page 13: ...To delete the limit setting of this position press the UP and DOWN button simultaneously until the lift begins to move briefly up and down 2 to 3 seconds c Adjust the lift to the require position whil...

Page 14: ...op at the position preset by the factory b To delete the limit setting of this position press the UP and DOWN button simultaneously until the lift begins to move briefly c Adjust the lift to the requi...

Page 15: ...opped in the position before setting more than 4 seconds c To delete the intermittent position that previously recorded press STOP button the lift will travel to the position that recorded d Press and...

Page 16: ...ntact Transmitter will be needed a Please refer the wiring diagram shown below to connect the dry contact transmitter Note The dry contact transmitter doesn t need to connect to motor They will intera...

Page 17: ...the three positions are correctly recorded by pressing UP DOWN and STOP buttons on hand held transmitter remote control e Press and hold the Programming button at the back of the hand held transmitter...

Page 18: ...ree positions are memorized by the Dry Contact Transmitter which automically quits its programming mode NOTE TO PROGRAMMER i Please program AMX or Crestron contact closure to trigger the lift by pulse...

Page 19: ...gins to move briefly b Press and hold PROG button on back of the wall switch until the lift begins to move briefly The setting is memorized by wall switch NOTE Please visit the following link for vide...

Page 20: ...ith dry contact transmitter where manual override of control system is required XLT wall switch front XLT wall switch back Please refer the diagram below to connect XLT wall mount switch and dry conta...

Page 21: ...20 XLT wall mount switch Dry Contact Transmitter...

Reviews: