Successfully flashing a new card results in a message similar to the one shown below. If the
command returns
Card Not Found
, perform a cold reboot, and retry. Otherwise, see the
Troubleshooting section.
Updating shell on card[0000:73:00.0]
INFO: ***Found 351 ELA Records
Enabled bitstream guard. Bitstream will not be loaded until flashing is
finished.
Erasing flash........................
Programming flash........................
Cleared bitstream guard. Bitstream now active.
Successfully flashed Card[0000:65:00.0]
1 Card(s) flashed successfully.
Cold reboot machine to load the new image on card(s)
7. Cold boot the machine to load the new firmware image on the FPGA.
IMPORTANT! Be sure to perform a cold boot to fully power off the machine and then power it on
again. The image will not boot from flash if the machine is only rebooted.
IMPORTANT! Initier un démarrage a froid en appuyant sur le bouton d’alimentation de la machine,
puis rallumer la machine. L’image flash ne démarrera pas sans un démarrage a froid.
WICHTIG! Führen Sie einen Kaltstart aus, indem Sie das Gerät vollständig aus und wieder
einschalten. Das Image startet nicht von Flash, wenn der Computer nur neu gestartet wird.
8. Update the SC firmware by re-running the update command in the previous update step.
sudo /opt/xilinx/xrt/bin/xbmgmt flash --update --shell <shell_name>
To regenerate the command, follow the steps given in the related topic, Generating the
xbmgmt flash --update Command.
If the SC is up to date, you will see the following message and no additional upgrade steps
are necessary.
Status: shell is up-to-date
Card(s) up-to-date and do not need to be flashed.
If the SC needs updating it will report the following message.
Status: SC needs updating
Current SC: <current_sc_version>
SC to be flashed: <new_sc_version>
Are you sure you wish to proceed? [y/n]: y
Chapter 4: Installing the Deployment Software
UG1370 (v1.7) December 9, 2020
Alveo U50 Data Center Accelerator Card Installation Guide
23