XP Series User's manual - Page 11
6.0 Operating the Channel Menus
Channel Linking – While holding down the
<<Menu
or
Menu>>
, more than
1 channel from the same group (Input or Output group) can be selected to
link the channels together. The green LEDs below the
Mute
buttons are lit
for the linked channels. Any modification of the data for the selected
channel will be applied to the linked channels as well. To cancel the linking,
simply deselect the desired channel while the
<<Menu
or
Menu>>
key is
still pressed, or just press the
Exit
key to deselect all channels.
6.1 Input Microphone Gain
3
LEVEL:
The level (or gain) ranges from 0dB to +45dB in 3dB steps. This level will
only have an affect on the input channel when Mic Input is selected from
the System Menu. Please refer to page 22 for more details.
6.2 Input/Output
Signal
LEVEL:
The level (or gain) ranges from -40.00dB to +15.00dB in 0.25dB steps.
POL:
The polarity (or phase) can be normal (+) or inverted (-).
3
For XP-2040M / 3060M / 4080M / 8080M models only.
I1:______ Signal
LEVEL:0.00dB
I1:______ Signal
POL:+
I1:______ Mic
LEVEL:0dB