background image

AM100 Series

User Guide

Xiamen Milesight IoT Co., Ltd.

Summary of Contents for Milesight AM100 Series

Page 1: ...AM100 Series User Guide Xiamen Milesight IoT Co Ltd ...

Page 2: ...r an extended period Otherwise the battery might leak and damage the device Never leave a discharged battery in the battery compartment The device must never be subjected to shocks or impacts Do not clean the device with detergents or solvents such as benzene or alcohol To clean the device wipe with a soft moistened cloth Use another soft dry cloth to wipe dry Declaration of Conformity AM100 serie...

Page 3: ...oc Version Description Apr 7 2020 V 1 0 Initial version May 19 2020 V 1 1 APP pictures replacement Aug 26 2020 V 1 2 Add screen display mode and configuration examples Firmware 1 17 Sept 14 2020 V 1 3 Add screen alarm settings Firmware 1 19 Nov 19 2020 V 2 0 Layout replace ...

Page 4: ...n via NFC 10 4 1 2 Template Settings 11 4 2 Configuration via PC 13 4 2 1 Log in the Toolbox 13 4 2 2 Basic Configuration 14 4 2 3 Upgrade 15 4 2 4 Template Settings 15 4 3 Configuration Examples 16 4 3 1 LoRa Channel Settings 16 4 3 2 Time Synchronization 17 4 3 3 Alarm Settings 18 5 Installation 19 5 1 Installation Note 19 5 2 Wall Mounting 19 6 Milesight IoT Cloud Management 19 6 1 Add a Milesi...

Page 5: ...stance while consuming very little power The user can obtain sensor data and view the trend of data change through Milesight IoT Cloud or through the user s own Network Server 1 2 Features Robust LoRa connectivity for indoor or HVAC environments Integrated multiple sensors like temperature humidity light air quality etc Easy configuration via NFC Visual display via E Ink screen Standard LoRaWAN su...

Page 6: ...w 2 3 E link Screen 2 3 1 Screen Description AM100 series provide 3 types of display modes AM104 Mode 1 Mode 2 Mode 3 AM107 Front Panel E ink screen NFC Area LoRa Antenna Internal PIR Sensor Light Sensor Back Panel Power button Battery Cover Mounting Holes Type C Port ...

Page 7: ...According to join status The device fails to join the network Temperature 1 min Humidity 1 min Luminance Level 0 0 5 lux Level 1 6 50 lux Level 2 51 100 lux Level 3 101 400 lux Level 4 401 700 lux Level 5 701 lux 1 min Total volatile organic compounds Level 0 0 100 ppb Level 1 101 200 ppb Level 2 201 250 ppb Level 3 251 300 ppb Level 4 301 350 ppb Level 5 351 400 ppb 1 min Show alarm when TVOC exc...

Page 8: ...ower button Quick press on the power button to switch the mode Mobile APP Go to APP menu Device Settings Basic Settings to select screen display mode Software Go to Toolbox menu Device Settings Basic Basic Settings to select screen display mode 2 3 Power Button AM100 series can be turned on off or reset by power button on the rear panel Function Action Turn On Press and hold the power button for m...

Page 9: ...e battery cover and install two new AA LR6 batteries Batteries can be replaced on the fly Note AM100 series can also be powered by type C USB port 5V 100mA When batteries and external power are both connected external power will power the device first USB port can t be used to charge battery ...

Page 10: ...Toolbox APP APP can be download on Google Play or Apple Store 4 1 1 Read Write Configuration via NFC 1 Enable NFC on the smartphone and open Toolbox APP 2 Attach the smartphone with NFC area to the device to read basic information Note Ensure your smartphone NFC area and it is recommended to take off phone case before using NFC 3 Click Write to change the configuration of AM sensor and attach the ...

Page 11: ...ttings are used for easy and quick device configuration in bulk Note Template function works only for sensors with the same model and LoRa frequency band 1 Go to Template page of APP and save current settings as a template 2 Attach the smartphone with NFC area to another device 3 Select the template file from Toolbox and click Write ...

Page 12: ...AM100 Series User Guide www milesight iot com 12 4 Keep the two devices close until the APP shows a successful prompt 5 Slide the template item left to edit or delete the template ...

Page 13: ...tware download 4 2 1 Log in the Toolbox Make sure Toolbox is downloaded on your computer Select one of the following methods to log in Toolbox USB Connection 1 Connect the AM sensor to computer via type C port 2 Select type as General and click password to log in Toolbox Default password 123456 NFC Connection 1 Connect the NFC reader to computer then attach the sensor to NFC area of the reader ...

Page 14: ... Click Read to read current data of the sensor 2 When you perform one of the following operations type the password and click Enter then wait a few seconds until toolbox shows a successful prompt Password is not needed if you connect it via type C port Turn on off the sensor Reset the sensor Sync the time Click Write to change settings Upgrade ...

Page 15: ...Upgrade to upgrade the device Note If NFC connection is selected please keep the two devices close and don t move them in order to get the best connectivity as possible when upgrading 4 2 4 Template Settings Note Template function works only for sensors with the same model and LoRa frequency band 1 Go to Maintenance Template and Reset page of Toolbox 2 Click Export to save the current settings as ...

Page 16: ...check default channel settings of AM104 AM107 Mobile APP Configuration Open Toolbox APP and go to Device Setting LoRaWAN Settings to change the frequency and channels Software Configuration Log in Toolbox and go to LoRaWAN Settings Channel to change frequency and channels Note If frequency is one of CN470 AU915 US915 you can enter the index of the channel that you want to enable in the input box m...

Page 17: ...60 All Enabling all channels Null Indicates that all channels are disabled 4 3 2 Time Synchronization Mobile APP Configuration Open Toolbox APP and go to Device Status to click sync to sync the time on the screen Software Configuration Log in Toolbox and go to Status page to sync the time on the screen ...

Page 18: ...ered AM107 will also show alarms of CO2 and TVOC on the screen Mobile APP Configuration Open Toolbox APP and go to Device Setting Threshold Settings to enable the threshold settings and input the threshold Software Configuration Log in Toolbox and go to Device Settings Basic Threshold Settings to enable the calibration and input the calibration value ...

Page 19: ...device right to the window or door If you have to you d better pull the curtain It is recommended to install at least 1 5m high from floor 5 2 Wall Mounting 1 Attach the mounting sticker to the wall 2 Mark the wall where the two mounting holes are according to the sticker s mark around 88mm Note The connecting line of two holes must be a horizontal line 3 Drive two screws into wall at the marks us...

Page 20: ...ateway 1 Enable Milesight type network server and Milesight IoT Cloud mode in gateway web GUI Note Ensure gateway has accessed the Internet 2 Go to My Devices page and click New Devices to add gateway to Milesight IoT Cloud via SN Gateway will be added under Gateways menu ...

Page 21: ... Milesight IoT Cloud 6 2 Add AM100 Series to Cloud 1 Go to Device My Devices and click Add Device Fill in the SN of AM sensor and select associated gateway 2 After sensor is connected to Milesight IoT Cloud you could check the device information and data and create dashboard for it ...

Page 22: ...nnel Type Data Example Description ff 01 Milesight Protocol Version 01 V1 16 Device SN 61 27 a2 17 41 32 Device SN is 6127a2174132 09 Hardware Version 01 40 V1 4 0a Software Version 01 14 V1 14 0f Device Type 00 Class A 18 Sensor Status 00 7f 00 all sensors 7f 0111 1111 means all sensors are open Channel Type Data Example Description 01 75 Battery Level 64 64 100 Battery level 100 03 67 Temperatur...

Page 23: ...vAddr The 5th to 12th digits of SN e g SN 61 26 A1 01 84 96 00 41 Then DevAddr A1018496 AppKey 5572404C696E6B4C6F52613230313823 07 7d CO2 67 04 67 04 04 67 1127 CO2 1127 ppm 08 7d TVOC 07 00 07 00 00 07 7 TVOC 7 ppb 09 73 Barometric Pressure 68 27 68 27 27 68 10088 Pressure 10088 0 1 1008 8hPa Channel Type Data Example Description ff 03 Set Reporting Interval b0 04 b0 04 04 b0 1200s 18 Enable disa...

Page 24: ...link Channels Model Channel Plan Channel Settings MHz AM104 470M AM107 470M CN470 470 3 489 3 All 95 channels AM104 868M AM107 868M EU868 868 1 868 3 868 5 RU864 868 9 869 1 IN865 865 0625 865 4025 865 6025 AM104 915M AM107 915M AU915 915 2 927 1 All 72 channels US915 902 3 914 2 All 72 channels KR920 922 1 922 3 922 5 AS923 923 2 923 4 END ...