FusionServer 2288H V6 Server
Technical White Paper
5 Hardware Description
2022-06-25
124
PCIe
Slot
CPU
PCIe
Standa
rds
Conne
ctor
Width
Bus
Width
Port
No.
Root
Port
(B/D/F
)
Device
(B/D/F
)
Slot
Size
Slot4
CPU1
PCIe
4.0
x16
x8
Port2C
4A/04/
0
4C/00/
0
HHHL
Slot5
CPU1
PCIe
4.0
x16
x8
Port3A
64/02/0 65/00/0 HHHL
Slot6
CPU1
PCIe
4.0
x16
x8
Port3C
64/04/0 66/00/0 HHHL
Slot7
CPU2
PCIe
4.0
x16
x16
Port0A
97/02/0 98/00/0 HHHL
Slot8
CPU2
PCIe
4.0
x16
x8
Port1A
B0/02/
0
B1/00/
0
HHHL
Slot9
CPU2
PCIe
4.0
x16
x8
Port1C
B0/04/
0
B2/00/
0
HHHL
Slot10
CPU2
PCIe
4.0
x16
x8
Port3A
E2/02/0 E3/00/0 FHHL
Slot11
CPU2
PCIe
4.0
x16
x8
Port3C
E2/04/0 E4/00/0 FHHL
⚫
The B/D/F (Bus/Device/Function Number) is the default value when the server is fully
configured with PCIe cards. The value may differ if the server is not fully configured
with PCIe cards or if a PCIe card with a PCI bridge is configured.
⚫
Root Port (B/D/F) indicates the B/D/F of an internal PCIe root port of the processor.
⚫
Device (B/D/F) indicates the B/D/F (bus address displayed on the OS) of an onboard or
extended PCIe device.
⚫
The PCIe x16 slots are compatible with PCIe x16, PCIe x8, PCIe x4, and PCIe x1 cards.
The PCIe cards are not forward compatible. That is, the PCIe slot width cannot be
smaller than the PCIe card link width.
⚫
The full-height half-length (FHHL) PCIe slots are compatible with FHHL PCIe cards
and half-height half-length (HHHL) PCIe cards.
⚫
The maximum power supply of each PCIe slot is 75 W.
5.1.8 PSUs
⚫
The server supports one or two PSUs.
⚫
The server supports AC or DC PSUs.
⚫
The PSUs are hot-swappable.
⚫
The server supports two PSUs in 1+1 redundancy.
⚫
PSUs of the same part number (P/N code) must be used in a server.
⚫
The PSUs are protected against short circuit. Double-pole fuse is provided for the PSUs
with dual input live wires.