Store the battery/battery pack in a cool, dry place. 

 

Stay away from children. If swallowed, contact doctor immediately. 

 

Avoid sealing the battery compartment and ensure ventilation 

 

Rechargeable battery maintenance instructions 

Periodic charge and discharge: If the unit is not used for a long time (when the battery is stored for more than 6 months), it is 

recommended to do it once for the Stim Unit. 

7. FAQ & Troubleshooting 

Q1. What should I do if the electrical stimulation intensity is weak? 

A. -Adjust the placement position. 

   -Adjust the electrical stimulation intensity through the Stim Unit or APP software. 

   -If the Stim Unit is running low, please charge it in time. 

   -Wet the skin and increase the electrical conductivity between the electrode and the skin. 

 

Q2. After turning on the training mode or gait mode on the unit, although the indicator light is on, there is no electrical stimulation 

reaction. 

A. -Check if the Stim Unit is tied and close to the skin. 

   -Check if the current intensity set by the Stim Unit is adjusted to the appropriate intensity. 

   -Add some water to the surface of the electrode sheet to increase the conductivity of the electrode sheet. 

 

Q3. What should I do if the skin in the area covered by the electrode and the Stim Unit band is severely red, stinging or allergic? 

A. Stop using it immediately. After observing for a period of time, if no abnormality is found, wait until the skin is completely 

improved before continuing to use the device. Remember to regularly ventilate the skin covered by the Stim Unit. 

 

Q4. The unit display battery icon is turned off after 1 second interval flashing. 

A. This indicates that the Stim Unit is running low and needs to be recharged. It takes about 3 hours for the unit to charge; after 

the battery is fully charged, the unit can last for about 10 hours. When the battery is low, please charge it in time. 

 

Q5. The Stim Unit LED light flashes quickly, what should I do if the main unit display “

”, “TBD Icon” flashes alternately? 

A. This indicator is a reminder that the electrode is off. Please check if the Stim Unit is fastened. Or the skin is too dry and needs 

to moisturize the skin. After re-fixing to the leg, press the main power stimulation adjustment button or press the stimulation 

adjustment button in APP software to continue. 

 

Q6. What happens when there is sporadic strong electrical stimulation? 

A. -The surface of the electrode is not wet enough to sprinkle some water on the surface. 

  -Check if the skin in the area covered by the electrode is red or has a wound. 

  -Check if the cuff of the main unit is loose and the position of the electrode is accurate. 

 

Q7. Why is there no electrical stimulation at the time of electrical stimulation? 

A. Usually because the cuff position has been moved or the gait mode has changed. Please wear the cuff again or reset the 

walking parameters. 

 

Q8. Can I use oil or lotion on my legs? 

A. No, please make sure the skin is clean before using the device and fully wet the adhesive surface of integrated electrode. 

8. Product Configuration 

8.1 Product specifications 

Communication method: Bluetooth 4.0 

Summary of Contents for G4

Page 1: ...Foot Drop System User Manual Caution Federal law restricts this device to sale by or on the order of a practitioner licensed by the law of the State in which he she practices to use or order the use...

Page 2: ...and Safety 3 2 Overviews 8 3 Product Illustration 9 4 Operation Instruction 12 5 Attentions 17 6 Care and Maintenance 17 7 FAQ Troubleshooting 18 8 Product Configuration 18 9 Product classification 19...

Page 3: ...the device battery accessory packing in accordance with the legal obligation in your area Contraindications Powered muscle stimulators should not be used on patients with cardiac demand pacemakers Do...

Page 4: ...ds 10mA cm2 r m s Please use with caution if the used areas have structural deformity This product should be conducted by doctors Patients should keep stable and not move while using this unit Patient...

Page 5: ...ctions may put the user at undue risk of injury Adverse Reactions Skin irritation and burns beneath the electrodes have been reported with the use of powered muscle stimulators Electromagnetic Compati...

Page 6: ...is used in such an environment Immunity test IEC60601 test level Compliance Guidance Electrostatic discharge ESD IEC 61000 4 2 6kV contact 8kV air 6kV contact 8kV air Floors should be wood concrete or...

Page 7: ...ermined by an electromagnetic site survey a should be less than the compliance level in each frequency range b interference may occur in the vicinity of equipment marked with the following symbol Radi...

Page 8: ...s the lack of ankle dorsiflexion in patients who have sustained damage to upper motor neurons or pathways to the spinal cord During the swing phase of walking the XFT 2001EA electrically stimulates th...

Page 9: ...for 1 4 hours a day every morning and evening 20 minutes each time 3rd week later Walk for 4 8 hours a day every morning and evening 20 minutes each time Note take off the cuff for 15 minutes after e...

Page 10: ...working states of the unit such as gait mode training mode electrode loose low battery icon electrical stimulation output icon electrical stimulation intensity etc 3 2 2 Indicators Power on indicatio...

Page 11: ...is low there will be a battery icon display battery display zero capacity at low voltage and flash at 1 second interval When the battery voltage is as low as the shutdown voltage the unit automaticall...

Page 12: ...When the Stim Unit is in the pause state press the Electrical Stimulation Intensity Adjustment Button to activate the electrical stimulation intensity press the up button to increase the electrical st...

Page 13: ...stool relax the affected leg and bend naturally Place the Stim Unit to correct position under the knee 4 1 3 3 Power on and operate Turn on Press and hold the switch mode composite button for 2 secon...

Page 14: ...it receives a reply from the Stim Unit and pauses the walk Continue The App sends the gait mode start at which time the current intensity given in the parameter setting is the current intensity before...

Page 15: ...lation stop the electrical stimulation by the release and continue to hold the electrical stimulation for continuous output The parameters that can be adjusted are the electrical stimulation intensity...

Page 16: ...pp sends an evaluation mode to start the command to the Stim Unit receives the Stim Unit reply and enters the evaluation work interface Stop After long press and stop for 2s send the evaluation mode s...

Page 17: ...in Care Before and after using the device please examine the skin it is normal that skin slightly turns red which shows faster blood flow Allergy Prevention Advice Do not position on the skin with mak...

Page 18: ...ng to use the device Remember to regularly ventilate the skin covered by the Stim Unit Q4 The unit display battery icon is turned off after 1 second interval flashing A This indicates that the Stim Un...

Page 19: ...ed 8 5 Product configuration Stim Unit 1pc Power Adapter 1set User manual 1pc 9 Product classification a Classified by type of electric shock internal power supply b The application part is classified...

Page 20: ...epaired by unauthorized repair store 3 When asking for warranty service please take with the warranty card It is charged according to the stipulation of the repair service of the warranty Please conta...

Page 21: ...trasse 80 D 20537 Hamburg Germany US Agent Yang LingYun 605 Sherwood Forest Place Cary North Carolina Cary NC 27519 Phone 919 4751044 Ext Email Usagency 126 Com Date 2018 12 17 Doc No XFT 2001EA E Ver...

Reviews: