Additional power functions
In addition to the normal operation of the XeRay™ XV-LX50 HID searchlight through
simple external manipulation, an internal dip switch array is provided for two group of
advanced functions (Factory settings – all switches set to ON).
The dip switch array can only be accessed after the battery has been removed. The dip switch
array is located on the PCB inside the XeRay™ XV-LX50 HID searchlight body, see picture
below:
In order to switch the individual dip switches a ball pen may be used.
XeRay™ XV-LX50 Output power preset
This setting is defined by selection of switch 1 and switch 2
Normal dual power mode, 35/50 W is selected
Switch 1
ON
Switch 2
ON
Permanent single power mode, 35 W is selected
Switch 1
ON
Switch 2
OFF
Permanent single power mode, 50 W is selected
Switch 1
OFF
Switch 2
ON
XeRay™ XV-LX50 Input power control function
This setting is defined by selection of switch 3 and switch 4, and will be released in the near
future (status aug. 2013). It will control external power sources and remote control.
Internal battery mode (factory setting)
Switch 3
ON
Switch 4
ON