4-4 LIU PBA
4-4-1. SUMMARY
LIU WIRE CONNECTS Main B’D’s MODEM AND
LINE PARTS, AND IMPEDANCE MATCHING (AC,
DC), RING DETECTION PART and LINE SEIZURE
(DIALER).
4-4-2. DC MATCHING PART
Normal movement range of LIU is 12mA ~ 9mA.
Adapting CTR21 standard, the regulation limits to
60mA CURRENT flow through the terminal.
Therefore, select (*:for EU PIT) Option to connect
necessary items then the current through LIU will not
exceed 60mA.
• CTR21 Standard(Europe) : 12mA~60mA
• OTHER Standard (U.S.) : 12mA~90mA
DC has a character to pass through the LINE. And
with Q1 (VN2410) GATE section’s LINE INPUT
corrent and Q1 Source connection to R20, can be
decided as follows :
• -V
DCR
= V
L1
+ I
LINE
X R20
(V
DCR
: Tip-Ring CD Voltage, I
LINE
: Current flow)
V
L1
:Line Input Voltage, V
L1
=V
BD1
+V
CE
(Q2)+V
DS
(Q1)
4-4-3. AC MATCHING PART
Basic LIU’s AC IMPEDANCE is 600 and uses R47.
48. C36 to possibly control combined IMPEDANCE.
• U.S. Usage : A terminal IMPEDANCE
→
600
Ω
(±30%)
• CTR21 : A Terminal IMPEDANCE
→
270+750
Ω
//150nF
4-4-4. DIALER PART
*MF DIAL
DTMF Dialing is controlled by MODEM and should be
selected by appropriate LEVEL and On-off Time
output based on each countries’ own National
specification.
• Freq. Tolerance : ±1.5%
High Group : 1209, 1336, 1477, 1633Hz
Low Group : 697, 770, 852, 941 Hz
*DP DIAL
Controls from MAIN through / DP-Terminal.
for U.S.Usage, set time to DF signal of 40:60 M/B. DP
signal is made of U6 (pcb817). The DC current which
flows thru Q2 Base is regulated by On/Off switch and
turns to DP dial signal with a COUPLER.
• CTR 21 does not have telephone capability but has
the number 3 and 4 Line Connection. No DP
condition but possibility to get approval only on
DTMF Dial based terminal.
4-4-5. RING DETECTION PART
RING SIGNALS from the LINE section (TIP,
RING)are further passed through C5, R3, ZD1, and
ZD2 and ends up at U9, (PC 814). U9 then detects
above RING SIGNAL and passes the output to MAIN
B’D. The wilre diagram’s C5 is RINGER CAPACITOR
and it normally uses 1UF/250V.
A R3 limits AC current and controls upper and lower
REN meter.
4-26
Circuit
U.S. Usage
CTR21
High Freq Level
-7.0 +1.0/-2.0
-9.0+2.0/-2.5
Low Freq Level
-9.0+1.0/-2.0
-11.0+2.5/-2.0
Summary of Contents for WorkCentre XK50cx
Page 47: ...4 20 Circuit Fig 4 2 6 TIMING DIAGRAM FOR EACH NOZZLE...
Page 69: ...Exploded Views and Parts List 6 1 Main Exploded View Parts List 6 2...
Page 71: ...Exploded Views and Parts List 6 2 MEC Cover Main Exploded View Parts List 6 4...
Page 73: ...Exploded Views and Parts List 6 3 Scanner Exploded View Parts List 6 6...
Page 77: ...Exploded Views and Parts List 6 4 Engine Exploded View Parts List 6 10...
Page 80: ...Exploded Views and Parts List 6 5 MEC Feeder Exploded View Parts List 6 13...
Page 82: ...Exploded Views and Parts List 6 6 MEC Cover Bottom Exploded View Parts List 6 15...
Page 84: ...Exploded Views and Parts List 6 7 Control Panel Ass y Exploded View Parts List 6 17...
Page 86: ...Exploded Views and Parts List 6 8 Packing Parts List 6 19...
Page 88: ...8 1 8 Block Diagrams 8 1 System Interconnection Diagram...