Wiring
Xerox Internal Use Only
Phaser 6600 and WorkCentre 6605
Service Manual
7-35
Bypass Tray (MSI)
Signal line name
Description
PRE REGI SENSED SIGNAL
Detect signal of paper in the Pre Registration section by the MSI
Sensor
MSI PAPER SENSED SIGNAL
Detect signal of paper in the MSI section by the MSI No Paper
Sensor
TAKEAWAY CL ON
ON/OFF signal of the Takeaway Clutch
MSI FEED SOLENOID ON
ON/OFF signal of the MSI Feed Sorenoid
MCU Board
PL18.1.13
P/J21
1
2
+5VDC
SG
3
9
PRE REGI SENSED SIGNAL
I/L +24VDC
10
MSI FEED SOLENOID ON
P/J211
3
2
1
Bypass Tray No
Paper Sensor
PL13.2.4
Bypass Tray No
Paper Sensor
PL13.2.4
1
2
J214
2
1
Bypass Tray Feed
Solenoid
PL13.2.9
+5VDC
4
5
+5VDC
SG
6
MSI PAPER SENSED SIGNAL
P/J212
3
2
1
Takeaway
Clutch
7
8
I/L +24VDC
TAKEAWAY CL ON
I/L +24VDC
J213
2
P213
1
2
1
Drive Assembly
PL3.1.1
Bypass Tray Harness Assembly
PL13.2.5
s6600-223
Summary of Contents for WorkCentre 6605
Page 2: ......
Page 4: ...Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual ii ...
Page 352: ...Image Quality Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 3 26 ...
Page 568: ...Parts Lists Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 5 64 ...
Page 644: ...Wiring Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 7 52 ...
Page 654: ...Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual A 10 ...
Page 660: ...Index Phaser 6600 and WorkCentre 6605 Service Manual I 6 ...
Page 661: ......