![background image](http://html1.mh-extra.com/html/xerox/phaser-4620/phaser-4620_service-manual_4208243167.webp)
5/2011
4-45
Phaser 4600/4620 Printer Service Manual
REP 7.30, REP 7.31
Repairs
Revision - Xerox Internal Use Only
Figure 1 Remove the Size Switch
REP 7.31 Upper Option Harness
Parts List on
PL 8.30 Item 10
Removal
WARNING
Use safe handling procedures when removing the module. Refer to
GP 15
. The module
is heavy.
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1.
Separate the option feeder from the printer
GP 15
.
2.
Remove the Tray.
3.
Remove the Right Cover,
REP 7.25
.
4.
Disconnect CN6 from the Feeder Board,
Figure 1
.
Figure 1 Disconnect the Upper Feeder Harness
5.
Remove 2 screws that secure the upper harness bracket to the chassis.
6.
Remove the harness from the chassis,
Figure 2
.