5/98
Fault Code Procedures
2-14
5750 DocuCare Service Manual
05-340
The control logic sensed an error in the self test routine of the Ram test.
Initial action:
Switch off the machine power.
If there is other equipment close by that may be generating electrical noise or radio frequency interference,
power it off also.
Contact Building Maintenance and have them verify the proper voltage at the machine plug.
Clean and inspect all corotrons for defects and ensure they are properly installed Section 5-Repairs.
Power the machine on.
If the problem still exists:
Place a service call.
ADF
Interlock
Fault
The control logic has sensed a problem with the ADF interlocks.
Initial action:
Inspect the feeder cover for any foreign material that would prevent the cover from closing correctly.
Inspect the feeder cover for damage or warping.
If the problem still exists:
Place a service call.
Status
Code
Description/Direction