8
Web Registration
Procedures
Once web threading is complete, you will need to register the web at the Primary CiPress™
and, if this is a tandem system, the Secondary CiPress™. Use the following procedure to
register the web prior to
Setting Up and Activating the Web Registration Module
1. Open the Infeed Module Front Door and access the lower front left cavity of the
Infeed Module.
2. With a tape, measure the actual width of the web to the nearest millimeter. Record
the value. Use this value for the
web width
3. Use the following formulas to determine the target web edge position from the inside
of the Infeed Module Front Frame Plate.
Note
The actual web edge position should be /- 3 mm of the target web edge
position calculated.
a) If the web is at the Left Rear Metal tab on the Primary CiPress™, use the following
formula:
(577 mm) - (web width) = result
. An example of the formula for 18 inch (120
mm) width web is:
(577 mm) - (457 mm) = 120 mm
.
b) If the web is at the Right Rear Metal tab on the Primary CiPress™, use the following
formula:
(610 mm) - (web width) = Result
. An example of the formula using 20 inch
width web is:
(610 mm) - (508 mm) = 102 mm
.
8-1
Xerox
®
CiPress™ 325 / 500 Production Inkjet System
Web Threading Guide
Summary of Contents for CiPress 325