Replacing the Fuser Module – Careful in this area may be HOT 

 

1. Power off the device, then disconnect the power cord from the 

device. 

2. Remove any paper from Tray 5. Open the left side door of the 

device. 

3. Locate the fuser module in the side of the printer. It is labeled R3. 

4. To release the fuser module, rotate the orange thumbscrews 

counterclockwise. The thumbscrews are at each end of the fuser 

module. 

5. Pull out the used fuser module. 

6. Unpack the new fuser module. Retain the packaging. 

7. Insert the new fuser module. 

8. To fasten the fuser module, rotate the orange thumbscrews 

clockwise. 

9. Place the used fuser module in the packaging that came with the 

new fuser module. 

10. Close the left side door of the device. Reconnect the device to the 

power cord, then power up the device. 

 

Replacing the Transfer Roller

 - When the Transfer Roller is replaced you must reset the Supply 

Counter. 

1. Power off the device, then disconnect the power cord from 

the device. 

2. Remove any paper from Tray 5. 

3. Open the left side door of the device. 

4. Locate the transfer roller in the printer side door. It is 

labeled R4. 

5. To remove the used transfer roller, squeeze the orange tabs 

at both ends of the transfer roller and lift the transfer roller 

out of the printer. 

6. Unpack the new transfer roller. Retain the packaging. 

7. To install the new transfer roller, position the transfer roller 

in the side door as shown. Squeeze the orange tabs at both 

ends of the transfer roller and press down gently, until it clicks 

into place. 

8. Place the used transfer roller in the packaging that came with the new transfer roller. 

9. Close the left side door of the device. 

10. Reset the supply life counter.  To reset the counter manually: 

1. Touch Device and then Tools. 

2. Touch Device Settings and then in the Features list, touch Supplies > Supply Counter 

Reset. 

3. Touch Transfer Roller and then Reset Counter. The Reset Confirmation Counter screen is 

displayed. 

4. To reset the counter, touch Reset. The counter is set to 100% remaining. 

5. Close the window. 

 