PREPARING THE INSTALLATION CHECKLISTS
Flow control
Allows you to set the communication protocol to one of the
following:
•
XON/XOFF (default communication protocol)
•
Robust XON/XOFF
•
DTR
For Robust XON/XOFF the printer will send an XON every second
while waiting for data. Robust XON/XOFF is available only when
the printer interface is set for PostScript mode.
Baud rate
Allows you to select the baud rate for the serial interface.
Data width
Allows you to set the word length to one of the following:
•
7-bit
•
8-bit (default).
Parity
Allows you to set the parity at to one of the following:
•
None (default)
•
Odd
•
Even.
DTR Polarity
If DTR is selected for flow control the DTR polarity can be set
either high or low.
Other I/O (Twinax or Coax) interface
Interface enablement
Allows you to enable or disable the Twinax or Coax interface.
When it is disabled no jobs will be processed from the Twinax or
Coax interface.
Print language selection
Allows you to select the following settings:
•
PS/PCL Sensing (default)
•
PostScript mode (Standard)
•
HP LaserJet emulation mode
•
PostScript mode (Binary)
•
Hexadecimal dump mode
•
PostScript mode (Tagged binary).
N
Note:
For 4215/MRP and 4219/MRP the Other I/O interface
must be enabled and set for PS/PCL sensing.
XEROX 4219/MRP AND 4215/MRP INSTALLATION PLANNING GUIDE
5-5
Summary of Contents for 4215
Page 6: ......
Page 11: ......
Page 12: ......
Page 23: ...INSTALLATION PLANNING TASKS XEROX 4219 MRP AND 4215 MRP INSTALLATION PLANNING GUIDE 2 5...
Page 33: ......
Page 39: ......
Page 55: ......
Page 57: ......
Page 59: ......
Page 61: ......
Page 63: ......
Page 65: ......
Page 67: ......
Page 69: ......
Page 71: ......
Page 79: ......
Page 83: ......