background image

 

 

14 

English 

The battery is connected to 
the charger and the LED’s 
burn but the charger does 
not work correctly.  

Mains voltage is too low. 

Measure the mains voltage. 
It should be higher than 
170VAC. 

Weak or no connection  
between the battery and 
the charger. 

Check the connection and 
the wires. 

Reversed polarization of 
the cables. 

Remove the connection. 
Replace the fuse in the  
charger (only use a fuse 
with the same value). 

Charger is set on the power 
supply mode. 

Set switch ‘charger/power 
supply in the correct 
position. 

No battery is connected but 
the green LED from ‘charge 
process’ burns when the 
charger is activated.  

The charger always gives a 
output voltage, irrespective 
of the present of a battery. 

Switch the charger off. 
Always firstly connect a 
battery.  

The battery isn’t charged 
fully, but the charged 
indicates the charging 
process is finished (float 
LED). 

The battery is defective. 

Measure the acid and, if 
necessary, replace the 
battery. 

The charger doesn’t switch 
to float. 

The battery is defective. 

Measure the acid and, if 
necessary, replace the 
battery. 

Battery cables to thin. 

Connect thicker cables. 

There are heavy consumers 
connected to the battery. 

Turn off as many users as 
possible or connect a 
heavier charger. 

battery is too heavy for the 
charger. 

Connect a heavier charger 
to the battery.  

 
 
 

MAINTENANCE  

 
The  charger  doesn’t  need  any  specific  maintenance.  When  cleaning  the  housing,  use  a 
(squeezed)  dry  cloth.  Remove  any  filth  and  dust  from  the  ventilation  openings  of  the 
charger.  Follow  the  instructions  of  the  manufacturer  when  using  and  handling  the 
battery.  CAUTION! A battery contains corrosive sulphuric acid. 
 

Important 

 

Check the charge status of battery charger on a regular basis. 

 

Check the cables and connection between the charger and battery regularly. 

 

Check the ventilation vents en fan on a regular basis. 

 

Check the degree of acidity of a non-maintenance free battery on a regular basis 

 

Summary of Contents for Econline EBC 12-20AT

Page 1: ...EBC serie AT model NL Gebruiksaanwijzing Pagina 2 GB Users manual Page 9 DE Gebrauchsanweisung Seite 16...

Page 2: ...dproces automatisch weer vervolgd Het verloop van de hierboven genoemde beveiligingen is sterk afhankelijk van de omgevingstemperatuur Kortsluitingbeveiliging op de uitgang De lader is beveiligd tegen...

Page 3: ...len is het belangrijk dat het laadproces altijd is afgerond Verbreek daarom de verbinding tussen lader en accu pas als het groene lampje float brandt Indien de lading tussentijds toch wordt onderbroke...

Page 4: ...lader zal dan n constante spanning afgeven Deze voeding spanning is eveneens in te stellen De maximale voedingsstroom die de lader kan leveren ligt gelijk aan de maximale laadstroom de eerste drie sch...

Page 5: ...monteren dient u de lader ge soleerd op te hangen Dit wil zeggen het huis van de lader mag geen contact maken met het schip om elektrolyse te voorkomen Aansluiting Bij de EBC lader wordt n kabelset m...

Page 6: ...arger on groen 230VAC aanwezig lader aan Float groen Druppellaadfase accu is vol Apsorption geel Nalaadfase Bulk rood Hoofdlaadfase ACCESSOIRES Bij de EBC AT versie is optioneel de LED display RD 06BC...

Page 7: ...anschakelen lader De acculader geeft altijd een spanning af onafhankelijk of er een accu aangesloten is Zet de lader uit Sluit altijd eerst een accu aan op de lader Schakel hierna de lader pas aan De...

Page 8: ...an de gebruiks aanwijzing opgelost had kunnen worden dan zijn wij genoodzaakt om de gemaakte kosten door te berekenen In geval van een defect kunt u de lader terug brengen naar uw leverancier of recht...

Page 9: ...e temperature protective devices operate will depend strongly on the ambient temperature Short circuit on the output The charger is protected from short circuit when no battery is connected even in th...

Page 10: ...ways completely finished As such the connection between the charger and the battery should only be broken when the green LED float lights If the charging process is interrupted before it is completed...

Page 11: ...ttery For this mode the sixth switch should be set to the ON position The power supply voltage can also be set The maximum power supply current is equally to the charging current de first three switch...

Page 12: ...t be insulated by suspension That is in order to avoid electrolysis the casing of the charger may not be in contact with the ship Connection One cable set is delivered with the EBC charger Extra cable...

Page 13: ...odels the LED display RD 06BC is optional available If connected it s possible to follow the charging process remotely The cable of this display should by pluged into the Remote display output PROBLEM...

Page 14: ...oat LED The battery is defective Measure the acid and if necessary replace the battery The charger doesn t switch to float The battery is defective Measure the acid and if necessary replace the batter...

Page 15: ...The charger must be send prepaid The EBC charger carries a two year warranty This warranty only covers the costs of parts and labour for the repair The warranty period is only valid when a copy of th...

Page 16: ...usgang Das Ladeger t ist gegen Kurzschlu gesichert wenn keine Batterie daran angeschlossen ist auch in Gegenwart einer Netzspannung Batterien hingegen sind nicht kurzschlu sicher Daher sollte man sich...

Page 17: ...der Ladevorgang auch wirklich abgeschlossen ist Unterbrechen Sie deshalb die Verbindung zwischen dem Lader und dem Akku erst dann wenn die gr ne LED float leuchtet Wenn der Ladevorgang zwischenzeitli...

Page 18: ...muss der Schalter 6 auf ON stehen Das Ladeger t gibt dann eine konstante Spannung ab Au erdem muss die Versorgungsspannung eingestellt werden Die maximale Stromspeisung des Ladeger ts entspricht dem m...

Page 19: ...ts zum Schutz vor Elektro lyse keinen Kontakt mit dem Schiff hat Anschlu Mit dem EBC Ladeger t wird ein Kabelset geliefert Zum Laden mehrerer Akkustationen k nnen Sie zus tzliche Kabel anbringen 1 Sch...

Page 20: ...RD 06BC angeschlossen ist kann der Ladevorgang bei einer Entfernung gelesen werden BEHEBUNG VON PROBLEMEN Problem m gliche Ursache Ein Akku ist an das Ladeger t angeschlossen und die LEDs leuchten abe...

Page 21: ...Endger te wie m glich aus oder schlie en Sie ein st rkeres Ladeger t an Das Ladeger t ist f r den Akku zu schwach Schlie en Sie ein st rkeres Ladeger t an den Akku an Wenn der EBC auch nach diesen Ma...

Page 22: ...s Ladeger t muss frankiert verschickt werden Die EBC Serie wird mit einer zweij hrigen Garantie geliefert die ab dem Verkaufsdatum gilt Diese Garantie bezieht sich nur auf die Komponenten beziehungswe...

Page 23: ...23...

Page 24: ...24...

Page 25: ...25 Laad karakteristiek Charge curve FASE 1 BULK CHARGING FASE 2 EQUALIZING FASE 3 FLOATCHARGING CHARGE TIME U VOLTAGE I CHARGE CURRENT T2 TIMER T1 I 100 RESET T1 U BATTERY I I 100...

Page 26: ...V2 3 Xenteq BV Banmolen 14 5768 ET Meijel NL Tel 31 0 77 4662067 Fax 31 0 77 4662845 www xenteq nl www acculader eu info xenteq nl...

Reviews: