8. Registers and Commands
The camera operation is controlled by values written in registers and commands, issued
start sequencer operation, etc. Most registers can be written and all registers can be read
back. Some registers, reflecting camera status, temperature, etc. can only be read.
The following tables contain a list of all registers with an indication of their function, legal
range, and default value. The Camera contains memory space to save a TBD number of
sets of register settings that can be updated by the user.
8.1. Identification Registers
Identification registers allow auto-detection and return versioning and house-keeping
information. The identification registers base address is: 0x0000.
Name
Offset
(hex)
R/W
Power- on
default
Description
Version
0000:0000
R
0
Register space version (always 0)
MAC.hi
0000:0008
R
00:1B:AA:01:xx:xx
MSB MAC values
MAC.lo
0000:000C
R
00:1B:AA:01:xx:xx
LSB MAC values
IP
0000:0024
R
Currently assigned IP address
Subnet
0000:0034
R
Currently assigned Subnet mask
Gateway
0000:0044
R
Currently assigned Gateway
Manuf
0000:0048
R
Xenics
Model
0000:0068
R
Camera model
Revision
0000:0088
R
Firmware revision
Info
0000:00A8
R
Info tag
ID
0000:00D8
R
Camera ID string
Name
0000:00E8
RW
Camera Name string
NetifCount
0000:0600
R
1
Available network interfaces (always 1)
PersistIP
0000:064C
RW
0.0.0.0
Fixed IPv4 Address
PersistSubNet
0000:065C
RW
0.0.0.0
Fixed IPv4 SubNet mask
PersistGateWay 0000:066C
RW
0.0.0.0
Fixed IPv4 Gateway
LinkSpeed
0000:0670
R
100000000
Network link speed (100MBit)
Table 8-1 Identification registers