4.7 LED Sequence Diagnostics
LED Sequence
Cause
Action Required
All LED’s OFF.
Drive may not have power, may
be faulty or may have been
power cycled or reset during a
firmware upgrade.
Make sure the drive is switched on. The power
on/off switch incorporates a green LED.
Check the power cord connection and replace
the cable if necessary. On external drives, you
can use the power cord from your monitor or
another device to check that the connection is
working.
If the power supply is present and all LEDs
remain off, power cycle or reset the drive. If it
still fails, call for service.
Ready and Clean OFF.
Drive and Tape FLASH.
The drive has failed to execute
power-on self test (POST).
Power cycle or reset the drive.
If the error condition reappears, call for service.