background image

Xeleum’s   Stairwell   Fixture   Control   Panel

Floor   X1   Dial   Switch:       

This   

dial   is   set   to   indicate   the   floor   

a   particular    fixture    is   being   

installed    on.      If   the   fixture    is   

being   installed   on   the   4

th

floor,    this   dial   would   be   set   to   

“4”.      If   the   fixture    is   being   

installed    on   the   23

rd

floor   this   

dial   would   be   set   to   “3”.

Stairwell    Dial   Switch:   

Some   building   

have   more   than   one   stairwell.       This   

switch   helps   to   keep   fixtures    in   one   

stairwell    from   talking   to   fixtures    in   

another    stairwell.      If   you   have   one   

stairwell,    use   a   small   straight   slot   

screwdriver    and   set   the   dial   to   “1”.      For   

multiple    stairwells   within    a   building,    set   

the   dial   accordingly.

Timer

:      Once   the   fixture    sees   motion   

within    the   stairwell   it   will   immediately   

illuminate    to   full   intensity.      A   small   

screwdriver    is   used   to   adjust   the   

”Timer”.      This   Timer   adjusts   the   length   

of   time   that   the   fixture    remains   on   at   

full   power   prior    to   returning    to   low   

power.      Turning    the   Timer   all   the   way   

to   the   left   (counter    clockwise)   will   keep   

the   fixture    on   at   high   power   for   only   

15-­‐seconds.      Turning   the   Timer   all   the   

way   to   the   right    (clockwise)   will   keep   

the   lights   on   at   full   power   for   5-­‐minutes   

after   the   sensor   sees   its   last   motion.      

The   time   can   also   be   set   anywhere   

between   15-­‐seconds    and   5-­‐minutes   by   

positioning    the   Timer   accordingly.

Status   Indicator    LED:      

This   

is   a   bi-­‐colored    LEDs   (Red   

and   Green).      This   LED   

provides   the   operator    with   

the   current    system   status.      

See   the   table   on   the   next   

page   for   a   detailed   

description    of   the   various   

indications.       

Self-­‐Diagnostic:       

Periodically    it’s   a   

good   idea   for   the   operators    to   

push   the   red   Self-­‐Diagnostic   

button    to   run   the   built-­‐in    testing   

program.      Results   of   the   Self-­‐

Diagnostic   test   are   reported    on   

the   Indicator    LEDs.      See   the   table   

on   the   next   page   for   a   detailed   

description    of   the   indicators.

Self-­‐Diagnostic    Status   LED:      

This   is   a   

bi-­‐colored    LEDs   (Red   and   Green).      

This   LED   provide   the   operator    with   

the   self-­‐diagnostic    test   status   and   

results.   See   the   table   on   the   next   

page   for   a   detailed   description    of   the   

indicators.       

5

Athena   Series   of   LED   

Stairwell   Fixtures

Installation   &   Operation   Guide

Floor   X10   Dial   Switch:       

This   dial   is   set   

to   indicate    the   floor    a   particular   

fixture    is   being   installed    on.      If   the   

fixture    is   being   installed    on   floors    1   -­‐

9,   this   dial   would   be   set   to   “0”.      If   the   

fixture    is   being   installed    on   floors    10   

– 19,   this   dial   would   be   set   to   “1”.      If   

it   is   being   installed    on   floors    20   – 29,   

this   dial   would   be   set   to   “2”.

EXAMPLE   #1:      If   a   fixture    is   being   installed   in   the   second   stairwell   of   a   building    on   the   17

th

floor,   the   dial   indicators   

would   be   set   like   this:         2         1         7.

EXAMPLE   #2:      If   a   fixture    is   being   installed   in   a   building    with   only   one   stairwell    on   the   landing   between   floors   5   and   

6,   the   dial   indicators    would   be   set   like   this:         1         0         5.

NOTE:      Landings      between   floors   should   have   the   same   dial   settings   as   the   floor    just   below   it…   i.e.   A   fixture   installed   

on   a   landing   between   floors   2   and   3   should   have   the   same   dial   settings   as   the   fixture   on   floor   2.