Xeleum’s Stairwell Fixture Control Panel
Floor X1 Dial Switch:
This
dial is set to indicate the floor
a particular fixture is being
installed on. If the fixture is
being installed on the 4
th
floor, this dial would be set to
“4”. If the fixture is being
installed on the 23
rd
floor this
dial would be set to “3”.
Stairwell Dial Switch:
Some building
have more than one stairwell. This
switch helps to keep fixtures in one
stairwell from talking to fixtures in
another stairwell. If you have one
stairwell, use a small straight slot
screwdriver and set the dial to “1”. For
multiple stairwells within a building, set
the dial accordingly.
Timer
: Once the fixture sees motion
within the stairwell it will immediately
illuminate to full intensity. A small
screwdriver is used to adjust the
”Timer”. This Timer adjusts the length
of time that the fixture remains on at
full power prior to returning to low
power. Turning the Timer all the way
to the left (counter clockwise) will keep
the fixture on at high power for only
15-‐seconds. Turning the Timer all the
way to the right (clockwise) will keep
the lights on at full power for 5-‐minutes
after the sensor sees its last motion.
The time can also be set anywhere
between 15-‐seconds and 5-‐minutes by
positioning the Timer accordingly.
Status Indicator LED:
This
is a bi-‐colored LEDs (Red
and Green). This LED
provides the operator with
the current system status.
See the table on the next
page for a detailed
description of the various
indications.
Self-‐Diagnostic:
Periodically it’s a
good idea for the operators to
push the red Self-‐Diagnostic
button to run the built-‐in testing
program. Results of the Self-‐
Diagnostic test are reported on
the Indicator LEDs. See the table
on the next page for a detailed
description of the indicators.
Self-‐Diagnostic Status LED:
This is a
bi-‐colored LEDs (Red and Green).
This LED provide the operator with
the self-‐diagnostic test status and
results. See the table on the next
page for a detailed description of the
indicators.
5
Athena Series of LED
Stairwell Fixtures
Installation & Operation Guide
Floor X10 Dial Switch:
This dial is set
to indicate the floor a particular
fixture is being installed on. If the
fixture is being installed on floors 1 -‐
9, this dial would be set to “0”. If the
fixture is being installed on floors 10
– 19, this dial would be set to “1”. If
it is being installed on floors 20 – 29,
this dial would be set to “2”.
EXAMPLE #1: If a fixture is being installed in the second stairwell of a building on the 17
th
floor, the dial indicators
would be set like this: 2 1 7.
EXAMPLE #2: If a fixture is being installed in a building with only one stairwell on the landing between floors 5 and
6, the dial indicators would be set like this: 1 0 5.
NOTE: Landings between floors should have the same dial settings as the floor just below it… i.e. A fixture installed
on a landing between floors 2 and 3 should have the same dial settings as the fixture on floor 2.
Revised: 1/6/14